LCOV - code coverage report
Current view: top level - EnergyPlus/Autosizing - CoolingWaterDesAirOutletHumRatSizing.cc (source / functions) Hit Total Coverage
Test: lcov.output.filtered Lines: 77 83 92.8 %
Date: 2023-01-17 19:17:23 Functions: 3 3 100.0 %

          Line data    Source code
       1             : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
       2             : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3             : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4             : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5             : // contributors. All rights reserved.
       6             : //
       7             : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8             : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9             : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10             : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11             : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12             : //
      13             : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14             : // provided that the following conditions are met:
      15             : //
      16             : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17             : //     conditions and the following disclaimer.
      18             : //
      19             : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20             : //     conditions and the following disclaimer in the documentation and/or other materials
      21             : //     provided with the distribution.
      22             : //
      23             : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24             : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25             : //     used to endorse or promote products derived from this software without specific prior
      26             : //     written permission.
      27             : //
      28             : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29             : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30             : //     reference solely to the software portion of its product, Licensee must refer to the
      31             : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32             : //     obtained under this License and may not use a different name for the software. Except as
      33             : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34             : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35             : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36             : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37             : //
      38             : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39             : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40             : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41             : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42             : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43             : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44             : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45             : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46             : // POSSIBILITY OF SUCH DAMAGE.
      47             : 
      48             : #include <EnergyPlus/Autosizing/CoolingWaterDesAirOutletHumRatSizing.hh>
      49             : #include <EnergyPlus/Data/EnergyPlusData.hh>
      50             : #include <EnergyPlus/DataEnvironment.hh>
      51             : #include <EnergyPlus/Psychrometrics.hh>
      52             : #include <EnergyPlus/UtilityRoutines.hh>
      53             : 
      54             : namespace EnergyPlus {
      55             : 
      56         443 : Real64 CoolingWaterDesAirOutletHumRatSizer::size(EnergyPlusData &state, Real64 _originalValue, bool &errorsFound)
      57             : {
      58         443 :     if (!this->checkInitialized(state, errorsFound)) {
      59           0 :         return 0.0;
      60             :     }
      61         443 :     this->preSize(state, _originalValue);
      62             : 
      63         443 :     if (this->curZoneEqNum > 0) {
      64          92 :         if (!this->wasAutoSized && !this->sizingDesRunThisZone) {
      65           0 :             this->autoSizedValue = _originalValue;
      66             :         } else {
      67          92 :             if (this->termUnitIU) {
      68           4 :                 Real64 TDpIn = Psychrometrics::PsyTdpFnWPb(state, this->dataDesInletAirHumRat, state.dataEnvrn->StdBaroPress);
      69           4 :                 if (TDpIn <= this->dataDesInletWaterTemp) {
      70           0 :                     this->autoSizedValue = this->dataDesInletAirHumRat;
      71             :                 } else {
      72           4 :                     this->autoSizedValue = min(Psychrometrics::PsyWFnTdbRhPb(state, this->dataDesOutletAirTemp, 0.9, state.dataEnvrn->StdBaroPress),
      73             :                                                this->dataDesInletAirHumRat);
      74             :                 }
      75             :             } else {
      76          88 :                 this->autoSizedValue = this->finalZoneSizing(this->curZoneEqNum).CoolDesHumRat;
      77             :             }
      78             :         }
      79         351 :     } else if (this->curSysNum > 0) {
      80         351 :         if (!this->wasAutoSized && !this->sizingDesRunThisAirSys) {
      81           0 :             this->autoSizedValue = _originalValue;
      82             :         } else {
      83         351 :             if (this->curOASysNum > 0) { // coil is in OA stream
      84          28 :                 if (this->outsideAirSys(this->curOASysNum).AirLoopDOASNum > -1) {
      85           1 :                     this->autoSizedValue = this->airloopDOAS[this->outsideAirSys(this->curOASysNum).AirLoopDOASNum].PrecoolHumRat;
      86             :                 } else {
      87          27 :                     this->autoSizedValue = this->finalSysSizing(this->curSysNum).PrecoolHumRat;
      88             :                 }
      89         323 :             } else if (this->dataDesOutletAirHumRat > 0.0) {
      90         323 :                 this->autoSizedValue = this->dataDesOutletAirHumRat;
      91             :             } else {
      92           0 :                 this->autoSizedValue = this->finalSysSizing(this->curSysNum).CoolSupHumRat;
      93             :             }
      94             :         }
      95             :     }
      96             : 
      97         443 :     if (this->wasAutoSized) {
      98         940 :         if (this->autoSizedValue > this->dataDesInletAirHumRat &&
      99         470 :             (UtilityRoutines::SameString(this->compType, "COIL:COOLING:WATER") ||
     100         438 :              UtilityRoutines::SameString(this->compType, "COIL:COOLING:WATER:DETAILEDGEOMETRY"))) {
     101             :             std::string msg =
     102          64 :                 this->callingRoutine + ":" + " Coil=\"" + this->compName + "\", Cooling Coil has leaving humidity ratio > entering humidity ratio.";
     103          32 :             this->addErrorMessage(msg);
     104          32 :             ShowWarningError(state, msg);
     105          32 :             msg = format("    Wair,in =  {:.6R} [kgWater/kgDryAir]", this->dataDesInletAirHumRat);
     106          32 :             this->addErrorMessage(msg);
     107          32 :             ShowContinueError(state, msg);
     108          32 :             msg = format("    Wair,out = {:.6R} [kgWater/kgDryAir]", this->autoSizedValue);
     109          32 :             this->addErrorMessage(msg);
     110          32 :             ShowContinueError(state, msg);
     111          32 :             if (this->dataDesInletAirHumRat > 0.016) {
     112           0 :                 this->autoSizedValue = 0.5 * this->dataDesInletAirHumRat;
     113             :             } else {
     114          32 :                 this->autoSizedValue = this->dataDesInletAirHumRat;
     115             :             }
     116          32 :             msg = "....coil leaving humidity ratio will be reset to:";
     117          32 :             this->addErrorMessage(msg);
     118          32 :             ShowContinueError(state, msg);
     119          32 :             msg = format("    Wair,out = {:.6R} [kgWater/kgDryAir]", this->autoSizedValue);
     120          32 :             this->addErrorMessage(msg);
     121          32 :             ShowContinueError(state, msg);
     122             :         }
     123             :         // check for dry coil and reset outlet humrat if needed
     124         876 :         Real64 desSatEnthAtWaterInTemp = Psychrometrics::PsyHFnTdbW(
     125         876 :             this->dataDesInletWaterTemp, Psychrometrics::PsyWFnTdpPb(state, this->dataDesInletWaterTemp, state.dataEnvrn->StdBaroPress));
     126         438 :         Real64 desHumRatAtWaterInTemp = Psychrometrics::PsyWFnTdbH(state, this->dataDesInletWaterTemp, desSatEnthAtWaterInTemp, this->callingRoutine);
     127         438 :         if (this->autoSizedValue < this->dataDesInletAirHumRat && desHumRatAtWaterInTemp > this->dataDesInletAirHumRat) {
     128          20 :             if (this->autoSizedValue < this->dataDesInletAirHumRat &&
     129          10 :                 (UtilityRoutines::SameString(this->compType, "COIL:COOLING:WATER") ||
     130           5 :                  UtilityRoutines::SameString(this->compType, "COIL:COOLING:WATER:DETAILEDGEOMETRY"))) {
     131          10 :                 std::string msg = this->callingRoutine + ":" + " Coil=\"" + this->compName +
     132             :                                   "\", Cooling Coil is running dry for sizing and has minimum humidity ratio at saturation for inlet chilled water "
     133          10 :                                   "temperature > design air entering humidity ratio.";
     134           5 :                 this->addErrorMessage(msg);
     135           5 :                 ShowWarningError(state, msg);
     136           5 :                 msg = format("    Wair,in =  {:.6R} [kgWater/kgDryAir]", this->dataDesInletAirHumRat);
     137           5 :                 this->addErrorMessage(msg);
     138           5 :                 ShowContinueError(state, msg);
     139           5 :                 msg = format("    Wair,out = {:.6R} [kgWater/kgDryAir]", this->autoSizedValue);
     140           5 :                 this->addErrorMessage(msg);
     141           5 :                 ShowContinueError(state, msg);
     142           5 :                 msg = format("    Inlet chilled water temperature = {:.3R} [C]", this->dataDesInletWaterTemp);
     143           5 :                 this->addErrorMessage(msg);
     144           5 :                 ShowContinueError(state, msg);
     145           5 :                 msg = format("    Minimum humidity ratio at saturation for inlet chilled water temperature = {:.6R} [kgWater/kgDryAir]",
     146           5 :                              desHumRatAtWaterInTemp);
     147           5 :                 this->addErrorMessage(msg);
     148           5 :                 ShowContinueError(state, msg);
     149           5 :                 this->autoSizedValue = this->dataDesInletAirHumRat;
     150           5 :                 msg = "....coil leaving humidity ratio will be reset to:";
     151           5 :                 this->addErrorMessage(msg);
     152           5 :                 ShowContinueError(state, msg);
     153           5 :                 msg = format("    Wair,out = {:.6R} [kgWater/kgDryAir]", this->autoSizedValue);
     154           5 :                 this->addErrorMessage(msg);
     155           5 :                 ShowContinueError(state, msg);
     156             :             }
     157             :         }
     158             :     }
     159         443 :     if (this->overrideSizeString) {
     160         443 :         if (this->isEpJSON) this->sizingString = "design_outlet_air_humidity_ratio [kgWater/kgDryAir]";
     161             :     }
     162         443 :     this->selectSizerOutput(state, errorsFound);
     163         443 :     if (this->isCoilReportObject)
     164         443 :         state.dataRptCoilSelection->coilSelectionReportObj->setCoilLvgAirHumRat(state, this->compName, this->compType, this->autoSizedValue);
     165         443 :     return this->autoSizedValue;
     166             : }
     167             : 
     168        2313 : } // namespace EnergyPlus

Generated by: LCOV version 1.13