LCOV - code coverage report
Current view: top level - EnergyPlus/Autosizing - HeatingWaterDesCoilWaterVolFlowUsedForUASizing.cc (source / functions) Hit Total Coverage
Test: lcov.output.filtered Lines: 23 26 88.5 %
Date: 2023-01-17 19:17:23 Functions: 3 3 100.0 %

          Line data    Source code
       1             : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
       2             : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3             : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4             : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5             : // contributors. All rights reserved.
       6             : //
       7             : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8             : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9             : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10             : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11             : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12             : //
      13             : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14             : // provided that the following conditions are met:
      15             : //
      16             : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17             : //     conditions and the following disclaimer.
      18             : //
      19             : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20             : //     conditions and the following disclaimer in the documentation and/or other materials
      21             : //     provided with the distribution.
      22             : //
      23             : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24             : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25             : //     used to endorse or promote products derived from this software without specific prior
      26             : //     written permission.
      27             : //
      28             : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29             : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30             : //     reference solely to the software portion of its product, Licensee must refer to the
      31             : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32             : //     obtained under this License and may not use a different name for the software. Except as
      33             : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34             : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35             : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36             : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37             : //
      38             : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39             : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40             : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41             : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42             : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43             : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44             : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45             : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46             : // POSSIBILITY OF SUCH DAMAGE.
      47             : 
      48             : #include <EnergyPlus/Autosizing/HeatingWaterDesCoilWaterVolFlowUsedForUASizing.hh>
      49             : #include <EnergyPlus/Data/EnergyPlusData.hh>
      50             : 
      51             : namespace EnergyPlus {
      52             : 
      53        2213 : Real64 HeatingWaterDesCoilWaterVolFlowUsedForUASizer::size(EnergyPlusData &state, Real64 _originalValue, bool &errorsFound)
      54             : {
      55        2213 :     if (!this->checkInitialized(state, errorsFound)) {
      56           0 :         return 0.0;
      57             :     }
      58        2213 :     this->preSize(state, _originalValue);
      59             : 
      60        2213 :     if (this->curZoneEqNum > 0) {
      61        1842 :         if (!this->wasAutoSized && !this->sizingDesRunThisZone) {
      62           0 :             this->autoSizedValue = _originalValue;
      63             :         } else {
      64        1842 :             if (this->termUnitSingDuct || this->zoneEqFanCoil) {
      65        1780 :                 this->autoSizedValue = this->dataWaterFlowUsedForSizing;
      66          62 :             } else if ((this->termUnitPIU || this->termUnitIU) && (this->curTermUnitSizingNum > 0)) {
      67          38 :                 this->autoSizedValue = this->dataWaterFlowUsedForSizing * this->termUnitSizing(this->curTermUnitSizingNum).ReheatLoadMult;
      68             :             } else {
      69          24 :                 this->autoSizedValue = this->dataWaterFlowUsedForSizing;
      70             :             }
      71             :         }
      72         371 :     } else if (this->curSysNum > 0) {
      73         371 :         if (!this->wasAutoSized && !this->sizingDesRunThisAirSys) {
      74           0 :             this->autoSizedValue = _originalValue;
      75             :         } else {
      76         371 :             this->autoSizedValue = this->dataWaterFlowUsedForSizing;
      77             :         }
      78             :     }
      79        2213 :     if (this->overrideSizeString) {
      80        2213 :         if (this->isEpJSON) this->sizingString = "design_water_volume_flow_rate_used_for_ua_sizing";
      81             :     }
      82        2213 :     this->selectSizerOutput(state, errorsFound);
      83        2213 :     if (this->isCoilReportObject) {
      84        4426 :         state.dataRptCoilSelection->coilSelectionReportObj->setCoilWaterFlowPltSizNum(
      85        2213 :             state, this->compName, this->compType, this->autoSizedValue, this->wasAutoSized, this->dataPltSizHeatNum, this->dataWaterLoopNum);
      86        2213 :         if (this->termUnitSingDuct || this->zoneEqFanCoil || ((this->termUnitPIU || this->termUnitIU) && this->curTermUnitSizingNum > 0)) {
      87        1818 :             state.dataRptCoilSelection->coilSelectionReportObj->setCoilReheatMultiplier(state, this->compName, this->compType, 1.0);
      88             :         }
      89             :     }
      90        2213 :     return this->autoSizedValue;
      91             : }
      92             : 
      93        2313 : } // namespace EnergyPlus

Generated by: LCOV version 1.13