Line data Source code
1 : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
2 : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
3 : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
4 : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
5 : // contributors. All rights reserved.
6 : //
7 : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
8 : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
9 : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
10 : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
11 : // derivative works, and perform publicly and display publicly, and to permit others to do so.
12 : //
13 : // Redistribution and use in source and binary forms, with or without modification, are permitted
14 : // provided that the following conditions are met:
15 : //
16 : // (1) Redistributions of source code must retain the above copyright notice, this list of
17 : // conditions and the following disclaimer.
18 : //
19 : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
20 : // conditions and the following disclaimer in the documentation and/or other materials
21 : // provided with the distribution.
22 : //
23 : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
24 : // the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
25 : // used to endorse or promote products derived from this software without specific prior
26 : // written permission.
27 : //
28 : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
29 : // without changes from the version obtained under this License, or (ii) Licensee makes a
30 : // reference solely to the software portion of its product, Licensee must refer to the
31 : // software as "EnergyPlus version X" software, where "X" is the version number Licensee
32 : // obtained under this License and may not use a different name for the software. Except as
33 : // specifically required in this Section (4), Licensee shall not use in a company name, a
34 : // product name, in advertising, publicity, or other promotional activities any name, trade
35 : // name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
36 : // similar designation, without the U.S. Department of Energy's prior written consent.
37 : //
38 : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
39 : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
40 : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
41 : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
42 : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
43 : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
44 : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
45 : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
46 : // POSSIBILITY OF SUCH DAMAGE.
47 :
48 : #ifndef DataGlobals_hh_INCLUDED
49 : #define DataGlobals_hh_INCLUDED
50 :
51 : // C++ Headers
52 : #include <functional>
53 : #include <iosfwd>
54 : #include <string>
55 :
56 : // EnergyPlus Headers
57 : #include <EnergyPlus/Data/BaseData.hh>
58 : #include <EnergyPlus/DataGlobalConstants.hh>
59 : #include <EnergyPlus/EnergyPlus.hh>
60 : #include <EnergyPlus/IOFiles.hh>
61 :
62 : namespace EnergyPlus {
63 :
64 : // Forward declarations
65 : struct EnergyPlusData;
66 :
67 : enum class BooleanSwitch
68 : {
69 : Invalid = -1,
70 : No,
71 : Yes,
72 : Num
73 : };
74 :
75 1542 : struct DataGlobal : BaseGlobalStruct
76 : {
77 : bool BeginDayFlag = false; // True at the start of each day, False after first time step in day
78 : bool BeginEnvrnFlag = false; // True at the start of each environment, False after first time step in environ
79 : bool BeginHourFlag = false; // True at the start of each hour, False after first time step in hour
80 : bool BeginSimFlag = false; // True until any actual simulation (full or sizing) has begun, False after first time step
81 : bool BeginTimeStepFlag = false; // True at the start of each time step, False after first subtime step of time step
82 : int DayOfSim = 0; // Counter for days (during the simulation)
83 : int CalendarYear = 0; // Calendar year of the current day of simulation
84 : std::string CalendarYearChr; // Calendar year of the current day of simulation (character -- for reporting)
85 : bool EndEnvrnFlag = false; // True at the end of each environment (last time step of last hour of last day of environ)
86 : bool EndDesignDayEnvrnsFlag = false; // True at the end of the last design day environment
87 : bool AnnualSimulation = false;
88 : std::string DayOfSimChr = "0"; // Counter for days (during the simulation) (character -- for reporting)
89 : bool runReadVars = false;
90 : bool DDOnlySimulation = false;
91 : bool outputEpJSONConversion = false;
92 : bool outputEpJSONConversionOnly = false;
93 : bool isEpJSON = false;
94 : bool preserveIDFOrder = true;
95 : bool stopSimulation = false;
96 : std::function<void(void *)> externalHVACManager;
97 : bool externalHVACManagerInitialized = false;
98 : DataGlobalConstants::KindOfSim KindOfSim = DataGlobalConstants::KindOfSim::Invalid;
99 : bool sizingAnalysisEioHeaderDoneOnce = false;
100 : bool EndDayFlag = false; // True at the end of each day (last time step of last hour of day)
101 : bool EndHourFlag = false; // True at the end of each hour (last time step of hour)
102 : int PreviousHour = 0; // Previous Hour Index
103 : int HourOfDay = 0; // Counter for hours in a simulation day
104 : Real64 WeightPreviousHour = 0.0; // Weighting of value for previous hour
105 : Real64 WeightNow = 0.0; // Weighting of value for current hour
106 : int NumOfDayInEnvrn = 0; // Number of days in the simulation for a particular environment
107 : bool OverrideTimestep = false; // True if PerformancePrecision object overrides the number of time steps in each hour
108 : int NumOfTimeStepInHour = 0; // Number of time steps in each hour of the simulation
109 : int NumOfZones = 0; // Total number of Zones for simulation
110 : int numSpaces = 0; // Total number of Spaces for simulation
111 : int numSpaceTypes = 0; // Number of unique space types
112 : int TimeStep = 0; // Counter for time steps (fractional hours)
113 : Real64 TimeStepZone = 0.0; // Zone time step in fractional hours
114 : bool WarmupFlag = false; // True during the warmup portion of a simulation
115 : int StdOutputRecordCount = 0; // Count of Standard output records
116 : int StdMeterRecordCount = 0; // Count of Meter output records
117 : bool ZoneSizingCalc = false; // TRUE if zone sizing calculation
118 : bool SysSizingCalc = false; // TRUE if system sizing calculation
119 : bool DoZoneSizing = false; // User input in SimulationControl object
120 : bool DoSystemSizing = false; // User input in SimulationControl object
121 : bool DoPlantSizing = false; // User input in SimulationControl object
122 : bool DoDesDaySim = false; // User input in SimulationControl object
123 : bool DoWeathSim = false; // User input in SimulationControl object
124 : bool DoPureLoadCalc = false; // if true, just run sizing and no full simulation of design days, or weather days, or HVAC Sizing Simulations
125 : bool DoHVACSizingSimulation = false; // User input in SimulationControl object
126 : int HVACSizingSimMaxIterations = 0; // User input in SimulationControl object
127 : bool WeathSimReq = false; // Input has a RunPeriod request
128 : bool DoOutputReporting = false; // TRUE if variables to be written out
129 : bool DoingSizing = false; // TRUE when "sizing" is being performed (some error messages won't be displayed)
130 : bool DoingHVACSizingSimulations = false; // true when HVAC Sizing Simulations are being performed.
131 : bool DoingInputProcessing = false; // TRUE when "IP" is being performed (some error messages are cached)
132 : bool DisplayAllWarnings = false; // True when selection for "DisplayAllWarnings" is entered (turns on other warning flags)
133 : bool DisplayExtraWarnings = false; // True when selection for "DisplayExtraWarnings" is entered
134 : bool DisplayUnusedObjects = false; // True when selection for "DisplayUnusedObjects" is entered
135 : bool DisplayUnusedSchedules = false; // True when selection for "DisplayUnusedSchedules" is entered
136 : bool DisplayAdvancedReportVariables = false; // True when selection for "DisplayAdvancedReportVariables" is entered
137 : bool DisplayZoneAirHeatBalanceOffBalance = false; // True when selection for "DisplayZoneAirHeatBalanceOffBalance" is entered
138 : bool DisplayInputInAudit = false; // True when environmental variable "DisplayInputInAudit" is used
139 : bool CreateMinimalSurfaceVariables = false; // True when selection for "CreateMinimalSurfaceVariables" is entered
140 : Real64 CurrentTime = 0.0; // CurrentTime, in fractional hours, from start of day. Uses Loads time step.
141 : int SimTimeSteps = 0; // Number of (Loads) timesteps since beginning of run period (environment).
142 : int MinutesPerTimeStep = 0; // Minutes per time step calculated from NumTimeStepInHour (number of minutes per load time step)
143 : Real64 TimeStepZoneSec = 0.0; // Seconds per time step
144 : bool MetersHaveBeenInitialized = false;
145 : bool KickOffSimulation = false; // Kick off simulation -- meaning run each environment for 1 or 2 time steps.
146 : bool KickOffSizing = false; // Kick off sizing -- meaning run each environment for 1 or 2 time steps.
147 : bool RedoSizesHVACSimulation = false; // doing kick off simulation for redoing sizes as part of sizing
148 : // bool FinalSizingHVACSizingSimIteration = false; // when doing HVAC sizing Simulation
149 : bool AnyEnergyManagementSystemInModel = false; // true if there is any EMS or Erl in model. otherwise false
150 : bool AnySurfPropOverridesInModel = false; // true if there is any EMS or Erl overriding the surface properties for any surface.
151 : bool AnyConstrOverridesInModel = false; // true if there is any EMS or Erl overriding the constructions for any surface.
152 : bool AndShadingControlInModel = false; // true if there is any window shading control for any fenestration surface
153 : bool AnyLocalEnvironmentsInModel = false; // true if there is any local environmental data objected defined in model, otherwise false
154 : bool AnyPlantInModel = false; // true if there are any plant or condenser loops in model, otherwise false
155 : bool AnyIdealCondEntSetPointInModel = false; // true if there is any ideal condenser entering set point manager in model.
156 : bool RunOptCondEntTemp = false; // true if the ideal condenser entering set point optimization is running
157 : bool CompLoadReportIsReq = false; // true if the extra sizing calcs are performed to create a "pulse" for the load component report
158 : bool isPulseZoneSizing = false; // true during the set of zone sizing calcs that include the "pulse" for the load component report
159 : bool doLoadComponentPulseNow = false; // true for the time step that is the "pulse" for the load component report
160 : bool ShowDecayCurvesInEIO = false; // true if the Radiant to Convective Decay Curves should appear in the EIO file
161 : bool AnySlabsInModel = false; // true if there are any zone-coupled ground domains in the input file
162 : bool AnyBasementsInModel = false; // true if there are any basements in the input file
163 : bool DoCoilDirectSolutions = false; // true if use coil direction solutions
164 : bool createPerfLog = false; // true if the _perflog.csv file should be created and a PerformancePrecisionTradeoffs object is used
165 : void (*fProgressPtr)(int const) = nullptr;
166 : void (*fMessagePtr)(std::string const &) = nullptr;
167 : std::function<void(int const)> progressCallback = nullptr;
168 : std::function<void(const std::string &)> messageCallback = nullptr;
169 : std::function<void(EnergyPlus::Error e, const std::string &)> errorCallback = nullptr;
170 : bool eplusRunningViaAPI = false;
171 : int NumOfWaterHeater = 0;
172 : bool CountNonZoneEquip = true;
173 : int FDsimDay = 0;
174 : int FDnumIterYears = 0;
175 : bool printConsoleOutput = true;
176 : bool installRootOverride = false;
177 : int numThread = 1;
178 : bool AirLoopHVACDOASUsedInSim = false;
179 :
180 0 : void clear_state() override
181 : {
182 0 : *this = DataGlobal();
183 0 : }
184 : };
185 :
186 : } // namespace EnergyPlus
187 :
188 : #endif
|