LCOV - code coverage report
Current view: top level - EnergyPlus/GroundTemperatureModeling - GroundTemperatureModelManager.cc (source / functions) Hit Total Coverage
Test: lcov.output.filtered Lines: 22 24 91.7 %
Date: 2023-01-17 19:17:23 Functions: 3 3 100.0 %

          Line data    Source code
       1             : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
       2             : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3             : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4             : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5             : // contributors. All rights reserved.
       6             : //
       7             : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8             : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9             : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10             : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11             : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12             : //
      13             : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14             : // provided that the following conditions are met:
      15             : //
      16             : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17             : //     conditions and the following disclaimer.
      18             : //
      19             : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20             : //     conditions and the following disclaimer in the documentation and/or other materials
      21             : //     provided with the distribution.
      22             : //
      23             : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24             : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25             : //     used to endorse or promote products derived from this software without specific prior
      26             : //     written permission.
      27             : //
      28             : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29             : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30             : //     reference solely to the software portion of its product, Licensee must refer to the
      31             : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32             : //     obtained under this License and may not use a different name for the software. Except as
      33             : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34             : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35             : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36             : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37             : //
      38             : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39             : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40             : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41             : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42             : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43             : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44             : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45             : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46             : // POSSIBILITY OF SUCH DAMAGE.
      47             : 
      48             : // C++ Headers
      49             : #include <memory>
      50             : #include <vector>
      51             : 
      52             : // EnergyPlus Headers
      53             : #include <EnergyPlus/Data/EnergyPlusData.hh>
      54             : #include <EnergyPlus/EnergyPlus.hh>
      55             : #include <EnergyPlus/GroundTemperatureModeling/BaseGroundTemperatureModel.hh>
      56             : #include <EnergyPlus/GroundTemperatureModeling/FiniteDifferenceGroundTemperatureModel.hh>
      57             : #include <EnergyPlus/GroundTemperatureModeling/GroundTemperatureModelManager.hh>
      58             : #include <EnergyPlus/GroundTemperatureModeling/KusudaAchenbachGroundTemperatureModel.hh>
      59             : #include <EnergyPlus/GroundTemperatureModeling/SiteBuildingSurfaceGroundTemperatures.hh>
      60             : #include <EnergyPlus/GroundTemperatureModeling/SiteDeepGroundTemperatures.hh>
      61             : #include <EnergyPlus/GroundTemperatureModeling/SiteFCFactorMethodGroundTemperatures.hh>
      62             : #include <EnergyPlus/GroundTemperatureModeling/SiteShallowGroundTemperatures.hh>
      63             : #include <EnergyPlus/GroundTemperatureModeling/XingGroundTemperatureModel.hh>
      64             : #include <EnergyPlus/UtilityRoutines.hh>
      65             : 
      66             : namespace EnergyPlus {
      67             : 
      68             : namespace GroundTemperatureManager {
      69             : 
      70             :     constexpr std::array<std::string_view, static_cast<int>(GroundTempObjType::Num)> groundTempModelNamesUC = {
      71             :         "SITE:GROUNDTEMPERATURE:UNDISTURBED:KUSUDAACHENBACH",
      72             :         "SITE:GROUNDTEMPERATURE:UNDISTURBED:FINITEDIFFERENCE",
      73             :         "SITE:GROUNDTEMPERATURE:BUILDINGSURFACE",
      74             :         "SITE:GROUNDTEMPERATURE:SHALLOW",
      75             :         "SITE:GROUNDTEMPERATURE:DEEP",
      76             :         "SITE:GROUNDTEMPERATURE:FCFACTORMETHOD",
      77             :         "SITE:GROUNDTEMPERATURE:UNDISTURBED:XING"};
      78             : 
      79             :     constexpr std::array<std::string_view, static_cast<int>(GroundTempObjType::Num)> groundTempModelNames = {
      80             :         "Site:GroundTemperature:Undisturbed:KusudaAchenbach",
      81             :         "Site:GroundTemperature:Undisturbed:FiniteDifference",
      82             :         "Site:GroundTemperature:BuildingSurface",
      83             :         "Site:GroundTemperature:Shallow",
      84             :         "Site:GroundTemperature:Deep",
      85             :         "Site:GroundTemperature:FCfactorMethod",
      86             :         "Site:GroundTemperature:Undisturbed:Xing"};
      87             : 
      88             :     std::shared_ptr<BaseGroundTempsModel>
      89        3119 :     GetGroundTempModelAndInit(EnergyPlusData &state, std::string_view const objectType_str, std::string const &objectName)
      90             :     {
      91             :         // SUBROUTINE INFORMATION:
      92             :         //       AUTHOR         Matt Mitchell
      93             :         //       DATE WRITTEN   Summer 2015
      94             :         //       MODIFIED       na
      95             :         //       RE-ENGINEERED  na
      96             : 
      97             :         // PURPOSE OF THIS SUBROUTINE:
      98             :         // Called by objects requiring ground temperature models. Determines type and calls appropriate factory method.
      99             : 
     100             :         // Set object type
     101             :         GroundTempObjType objectType =
     102        3119 :             static_cast<GroundTempObjType>(getEnumerationValue(groundTempModelNamesUC, UtilityRoutines::MakeUPPERCase(objectType_str)));
     103             : 
     104        3119 :         assert(objectType != GroundTempObjType::Invalid);
     105             : 
     106        3119 :         int numGTMs = state.dataGrndTempModelMgr->groundTempModels.size();
     107             : 
     108             :         // Check if this instance of this model has already been retrieved
     109        7885 :         for (int i = 0; i < numGTMs; ++i) {
     110        9532 :             auto currentModel(state.dataGrndTempModelMgr->groundTempModels[i]);
     111             :             // Check if the type and name match
     112        4766 :             if (objectType == currentModel->objectType && objectName == currentModel->objectName) {
     113           0 :                 return state.dataGrndTempModelMgr->groundTempModels[i];
     114             :             }
     115             :         }
     116             : 
     117             :         // If not found, create new instance of the model
     118        3119 :         if (objectType == GroundTempObjType::KusudaGroundTemp) {
     119          33 :             return KusudaGroundTempsModel::KusudaGTMFactory(state, objectName);
     120        3086 :         } else if (objectType == GroundTempObjType::FiniteDiffGroundTemp) {
     121           1 :             return FiniteDiffGroundTempsModel::FiniteDiffGTMFactory(state, objectName);
     122        3085 :         } else if (objectType == GroundTempObjType::SiteBuildingSurfaceGroundTemp) {
     123         771 :             return SiteBuildingSurfaceGroundTemps::BuildingSurfaceGTMFactory(state, objectName);
     124        2314 :         } else if (objectType == GroundTempObjType::SiteShallowGroundTemp) {
     125         771 :             return SiteShallowGroundTemps::ShallowGTMFactory(state, objectName);
     126        1543 :         } else if (objectType == GroundTempObjType::SiteDeepGroundTemp) {
     127         771 :             return SiteDeepGroundTemps::DeepGTMFactory(state, objectName);
     128         772 :         } else if (objectType == GroundTempObjType::SiteFCFactorMethodGroundTemp) {
     129         771 :             return SiteFCFactorMethodGroundTemps::FCFactorGTMFactory(state, objectName);
     130           1 :         } else if (objectType == GroundTempObjType::XingGroundTemp) {
     131           1 :             return XingGroundTempsModel::XingGTMFactory(state, objectName);
     132             :         } else {
     133           0 :             assert(false);
     134             :             return nullptr;
     135             :         }
     136             :     }
     137             : 
     138             : } // namespace GroundTemperatureManager
     139             : 
     140        2313 : } // namespace EnergyPlus

Generated by: LCOV version 1.13