LCOV - code coverage report
Current view: top level - EnergyPlus - NonZoneEquipmentManager.cc (source / functions) Hit Total Coverage
Test: lcov.output.filtered Lines: 16 16 100.0 %
Date: 2023-01-17 19:17:23 Functions: 3 3 100.0 %

          Line data    Source code
       1             : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
       2             : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3             : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4             : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5             : // contributors. All rights reserved.
       6             : //
       7             : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8             : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9             : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10             : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11             : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12             : //
      13             : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14             : // provided that the following conditions are met:
      15             : //
      16             : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17             : //     conditions and the following disclaimer.
      18             : //
      19             : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20             : //     conditions and the following disclaimer in the documentation and/or other materials
      21             : //     provided with the distribution.
      22             : //
      23             : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24             : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25             : //     used to endorse or promote products derived from this software without specific prior
      26             : //     written permission.
      27             : //
      28             : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29             : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30             : //     reference solely to the software portion of its product, Licensee must refer to the
      31             : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32             : //     obtained under this License and may not use a different name for the software. Except as
      33             : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34             : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35             : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36             : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37             : //
      38             : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39             : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40             : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41             : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42             : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43             : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44             : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45             : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46             : // POSSIBILITY OF SUCH DAMAGE.
      47             : 
      48             : // EnergyPlus Headers
      49             : #include <EnergyPlus/Data/EnergyPlusData.hh>
      50             : #include <EnergyPlus/DataGlobals.hh>
      51             : #include <EnergyPlus/InputProcessing/InputProcessor.hh>
      52             : #include <EnergyPlus/NonZoneEquipmentManager.hh>
      53             : #include <EnergyPlus/WaterThermalTanks.hh>
      54             : #include <EnergyPlus/WaterUse.hh>
      55             : 
      56             : namespace EnergyPlus {
      57             : 
      58             : namespace NonZoneEquipmentManager {
      59             : 
      60             :     // MODULE INFORMATION:
      61             :     //       AUTHOR         Peter Graham Ellis
      62             :     //       DATE WRITTEN   January 2004
      63             :     //       MODIFIED       Hudson, ORNL July 2007
      64             :     //       RE-ENGINEERED  na
      65             : 
      66             :     // PURPOSE OF THIS MODULE:
      67             : 
      68             :     // METHODOLOGY EMPLOYED: na
      69             : 
      70             :     // REFERENCES: na
      71             :     // OTHER NOTES: na
      72             :     // USE STATEMENTS: na
      73             : 
      74             :     // Data
      75             :     // MODULE PARAMETER DEFINITIONS: na
      76             :     // MODULE VARIABLE DECLARATIONS: na
      77             : 
      78             :     // SUBROUTINE SPECIFICATIONS:
      79             : 
      80             :     // MODULE SUBROUTINES:
      81             : 
      82             :     // Functions
      83             : 
      84     6279752 :     void ManageNonZoneEquipment(EnergyPlusData &state,
      85             :                                 bool const FirstHVACIteration,
      86             :                                 bool &SimNonZoneEquipment // Simulation convergence flag
      87             :     )
      88             :     {
      89             : 
      90             :         // SUBROUTINE INFORMATION:
      91             :         //       AUTHOR         Dan Fisher
      92             :         //       DATE WRITTEN   Sept. 2000
      93             :         //       RE-ENGINEERED  Richard Liesen
      94             :         //       DATE MODIFIED  February 2003
      95             :         //       MODIFIED       Hudson, ORNL July 2007
      96             :         //       MODIFIED       B. Griffith, NREL, April 2008,
      97             :         //                      added calls for just heat recovery part of chillers
      98             :         //       MODIFIED       Removed much for plant upgrade, 2011
      99             : 
     100             :         // PURPOSE OF THIS SUBROUTINE:
     101             :         // This routine checks the input file for any non-zone equipment objects and gets their input.
     102             :         // Zone equipment objects are generally triggered to "get input" when they are called for simulation
     103             :         // by the ZoneEquipmentManager because they are referenced by a Zone Equipment List.  In the case of
     104             :         // the NonZoneEquipmentManager, it does not yet have a list of non-zone equipment, so it must make
     105             :         // one here before it knows what to call for simulation.
     106             : 
     107             :         // Using/Aliasing
     108             :         using WaterThermalTanks::SimulateWaterHeaterStandAlone;
     109             :         using WaterUse::SimulateWaterUse;
     110             : 
     111             :         // SUBROUTINE LOCAL VARIABLE DECLARATIONS:
     112             :         int WaterHeaterNum; // Water heater object number
     113     6279752 :         auto &NumOfWaterHeater = state.dataGlobal->NumOfWaterHeater;
     114     6279752 :         auto &CountNonZoneEquip = state.dataGlobal->CountNonZoneEquip;
     115             : 
     116     6279752 :         if (CountNonZoneEquip) {
     117        2313 :             NumOfWaterHeater = state.dataInputProcessing->inputProcessor->getNumObjectsFound(state, "WaterHeater:Mixed") +
     118        1542 :                                state.dataInputProcessing->inputProcessor->getNumObjectsFound(state, "WaterHeater:Stratified");
     119         771 :             CountNonZoneEquip = false;
     120             :         }
     121             : 
     122     6279752 :         SimulateWaterUse(state, FirstHVACIteration); // simulate non-plant loop water use.
     123             : 
     124     6279752 :         if (!state.dataGlobal->ZoneSizingCalc) {
     125     6712558 :             for (WaterHeaterNum = 1; WaterHeaterNum <= NumOfWaterHeater; ++WaterHeaterNum) {
     126     1420050 :                 SimulateWaterHeaterStandAlone(state, WaterHeaterNum, FirstHVACIteration);
     127             :             }
     128             :         }
     129             : 
     130     6279752 :         if (FirstHVACIteration) {
     131     3626116 :             SimNonZoneEquipment = true;
     132             :         } else {
     133     2653636 :             SimNonZoneEquipment = false;
     134             :         }
     135     6279752 :     }
     136             : 
     137             : } // namespace NonZoneEquipmentManager
     138             : 
     139        2313 : } // namespace EnergyPlus

Generated by: LCOV version 1.13