Line data Source code
1 : // EnergyPlus, Copyright (c) 1996-2023, The Board of Trustees of the University of Illinois,
2 : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
3 : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
4 : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
5 : // contributors. All rights reserved.
6 : //
7 : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
8 : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
9 : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
10 : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
11 : // derivative works, and perform publicly and display publicly, and to permit others to do so.
12 : //
13 : // Redistribution and use in source and binary forms, with or without modification, are permitted
14 : // provided that the following conditions are met:
15 : //
16 : // (1) Redistributions of source code must retain the above copyright notice, this list of
17 : // conditions and the following disclaimer.
18 : //
19 : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
20 : // conditions and the following disclaimer in the documentation and/or other materials
21 : // provided with the distribution.
22 : //
23 : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
24 : // the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
25 : // used to endorse or promote products derived from this software without specific prior
26 : // written permission.
27 : //
28 : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
29 : // without changes from the version obtained under this License, or (ii) Licensee makes a
30 : // reference solely to the software portion of its product, Licensee must refer to the
31 : // software as "EnergyPlus version X" software, where "X" is the version number Licensee
32 : // obtained under this License and may not use a different name for the software. Except as
33 : // specifically required in this Section (4), Licensee shall not use in a company name, a
34 : // product name, in advertising, publicity, or other promotional activities any name, trade
35 : // name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
36 : // similar designation, without the U.S. Department of Energy's prior written consent.
37 : //
38 : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
39 : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
40 : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
41 : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
42 : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
43 : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
44 : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
45 : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
46 : // POSSIBILITY OF SUCH DAMAGE.
47 :
48 : #include <EnergyPlus/Data/EnergyPlusData.hh>
49 : #include <EnergyPlus/DataIPShortCuts.hh>
50 : #include <EnergyPlus/InputProcessing/InputProcessor.hh>
51 : #include <EnergyPlus/WindowModel.hh>
52 :
53 : namespace EnergyPlus {
54 :
55 3 : template <> EnumParser<WindowManager::WindowsModel>::EnumParser()
56 : {
57 3 : m_Map["BUILTINWINDOWSMODEL"] = WindowManager::WindowsModel::BuiltIn;
58 3 : m_Map["EXTERNALWINDOWSMODEL"] = WindowManager::WindowsModel::External;
59 3 : }
60 :
61 : namespace WindowManager {
62 :
63 : /////////////////////////////////////////////////////////////////////////////////////////
64 : // CWindowModel
65 : /////////////////////////////////////////////////////////////////////////////////////////
66 :
67 771 : CWindowModel::CWindowModel() : m_Model(WindowsModel::BuiltIn)
68 : {
69 771 : }
70 :
71 771 : std::unique_ptr<CWindowModel> CWindowModel::WindowModelFactory(EnergyPlusData &state, std::string const &objectName)
72 : {
73 : // SUBROUTINE INFORMATION:
74 : // AUTHOR Simon Vidanovic
75 : // DATE WRITTEN July 2016
76 : // MODIFIED na
77 : // RE-ENGINEERED na
78 :
79 : // PURPOSE OF THIS SUBROUTINE:
80 : // Reads input and creates instance of WindowModel object
81 : int NumNums;
82 : int NumAlphas;
83 : int IOStat;
84 :
85 771 : auto aModel = std::make_unique<CWindowModel>();
86 771 : int numCurrModels = state.dataInputProcessing->inputProcessor->getNumObjectsFound(state, objectName);
87 771 : if (numCurrModels > 0) {
88 9 : state.dataInputProcessing->inputProcessor->getObjectItem(
89 6 : state, objectName, 1, state.dataIPShortCut->cAlphaArgs, NumAlphas, state.dataIPShortCut->rNumericArgs, NumNums, IOStat);
90 6 : EnumParser<WindowsModel> aParser;
91 3 : aModel->m_Model = aParser.StringToEnum(state, state.dataIPShortCut->cAlphaArgs(1));
92 : }
93 :
94 771 : return aModel;
95 : }
96 :
97 0 : WindowsModel CWindowModel::getWindowsModel() const
98 : {
99 0 : return m_Model;
100 : }
101 :
102 30599313 : bool CWindowModel::isExternalLibraryModel() const
103 : {
104 30599313 : return m_Model == WindowsModel::External;
105 : }
106 :
107 0 : void CWindowModel::setExternalLibraryModel(WindowsModel model)
108 : {
109 0 : m_Model = model;
110 0 : }
111 :
112 : /////////////////////////////////////////////////////////////////////////////////////////
113 : // CWindowOpticalModel
114 : /////////////////////////////////////////////////////////////////////////////////////////
115 :
116 771 : CWindowOpticalModel::CWindowOpticalModel() : m_Model(WindowsOpticalModel::Simplified)
117 : {
118 771 : }
119 :
120 771 : std::unique_ptr<CWindowOpticalModel> CWindowOpticalModel::WindowOpticalModelFactory(EnergyPlusData &state)
121 : {
122 : // Process input data and counts if number of complex fenestration objects is greater
123 : // than zero in which case it will use BSDF window model
124 771 : auto aModel = std::make_unique<CWindowOpticalModel>();
125 771 : int numCurrModels = state.dataInputProcessing->inputProcessor->getNumObjectsFound(state, "Construction:ComplexFenestrationState");
126 :
127 771 : if (numCurrModels > 0) {
128 10 : aModel->m_Model = WindowsOpticalModel::BSDF;
129 : }
130 :
131 771 : return aModel;
132 : }
133 :
134 0 : WindowsOpticalModel CWindowOpticalModel::getWindowsOpticalModel() const
135 : {
136 0 : return m_Model;
137 : }
138 :
139 2071 : bool CWindowOpticalModel::isSimplifiedModel() const
140 : {
141 2071 : return (m_Model == WindowsOpticalModel::Simplified);
142 : }
143 :
144 : } // namespace WindowManager
145 :