LCOV - code coverage report
Current view: top level - EnergyPlus - ElectricBaseboardRadiator.hh (source / functions) Hit Total Coverage
Test: lcov.output.filtered Lines: 5 11 45.5 %
Date: 2024-08-24 18:31:18 Functions: 2 3 66.7 %

          Line data    Source code
       1             : // EnergyPlus, Copyright (c) 1996-2024, The Board of Trustees of the University of Illinois,
       2             : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3             : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4             : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5             : // contributors. All rights reserved.
       6             : //
       7             : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8             : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9             : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10             : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11             : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12             : //
      13             : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14             : // provided that the following conditions are met:
      15             : //
      16             : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17             : //     conditions and the following disclaimer.
      18             : //
      19             : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20             : //     conditions and the following disclaimer in the documentation and/or other materials
      21             : //     provided with the distribution.
      22             : //
      23             : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24             : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25             : //     used to endorse or promote products derived from this software without specific prior
      26             : //     written permission.
      27             : //
      28             : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29             : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30             : //     reference solely to the software portion of its product, Licensee must refer to the
      31             : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32             : //     obtained under this License and may not use a different name for the software. Except as
      33             : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34             : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35             : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36             : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37             : //
      38             : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39             : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40             : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41             : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42             : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43             : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44             : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45             : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46             : // POSSIBILITY OF SUCH DAMAGE.
      47             : 
      48             : #ifndef ElectricBaseboardRadiator_hh_INCLUDED
      49             : #define ElectricBaseboardRadiator_hh_INCLUDED
      50             : 
      51             : // ObjexxFCL Headers
      52             : #include <ObjexxFCL/Array1D.hh>
      53             : 
      54             : // EnergyPlus Headers
      55             : #include <EnergyPlus/Data/BaseData.hh>
      56             : #include <EnergyPlus/DataGlobals.hh>
      57             : #include <EnergyPlus/EnergyPlus.hh>
      58             : 
      59             : namespace EnergyPlus {
      60             : 
      61             : // Forward declarations
      62             : struct EnergyPlusData;
      63             : 
      64             : namespace ElectricBaseboardRadiator {
      65             : 
      66             :     struct ElecBaseboardParams
      67             :     {
      68             :         // Members
      69             :         std::string EquipName;
      70             :         int EquipType = 0;
      71             :         std::string Schedule;
      72             :         Array1D_string SurfaceName;
      73             :         Array1D_int SurfacePtr;
      74             :         int ZonePtr = 0;
      75             :         int SchedPtr = 0;
      76             :         int TotSurfToDistrib = 0;
      77             :         Real64 NominalCapacity = 0.0;
      78             :         Real64 BaseboardEfficiency = 0.0;
      79             :         Real64 AirInletTemp = 0.0;
      80             :         Real64 AirInletHumRat = 0.0;
      81             :         Real64 AirOutletTemp = 0.0;
      82             :         Real64 ElecUseLoad = 0.0;
      83             :         Real64 ElecUseRate = 0.0;
      84             :         Real64 FracRadiant = 0.0;
      85             :         Real64 FracConvect = 0.0;
      86             :         Real64 FracDistribPerson = 0.0;
      87             :         Real64 TotPower = 0.0;
      88             :         Real64 Power = 0.0;
      89             :         Real64 ConvPower = 0.0;
      90             :         Real64 RadPower = 0.0;
      91             :         Real64 TotEnergy = 0.0;
      92             :         Real64 Energy = 0.0;
      93             :         Real64 ConvEnergy = 0.0;
      94             :         Real64 RadEnergy = 0.0;
      95             :         Array1D<Real64> FracDistribToSurf;
      96             :         int HeatingCapMethod = 0;           // - Method for electric baseboard heating capacity scalable sizing calculation
      97             :         Real64 ScaledHeatingCapacity = 0.0; // - scaled maximum heating capacity {W} or scalable variable for sizing in {-}, or {W/m2}
      98             :         bool MySizeFlag = true;
      99             :         bool MyEnvrnFlag = true;
     100             :         bool CheckEquipName = true;
     101             :         Real64 ZeroBBSourceSumHATsurf = 0.0; // used in baseboard energy balance
     102             :         // Record keeping variables used to calculate QBBRadSrcAvg locally
     103             :         Real64 QBBElecRadSource = 0.0;   // Need to keep the last value in case we are still iterating
     104             :         Real64 QBBElecRadSrcAvg = 0.0;   // Need to keep the last value in case we are still iterating
     105             :         Real64 LastSysTimeElapsed = 0.0; // Need to keep the last value in case we are still iterating
     106             :         Real64 LastTimeStepSys = 0.0;    // Need to keep the last value in case we are still iterating
     107             :         Real64 LastQBBElecRadSrc = 0.0;  // Need to keep the last value in case we are still iterating
     108             :     };
     109             : 
     110             :     struct ElecBaseboardNumericFieldData
     111             :     {
     112             :         // Members
     113             :         Array1D_string FieldNames;
     114             : 
     115             :         // Default Constructor
     116           1 :         ElecBaseboardNumericFieldData()
     117           1 :         {
     118           1 :         }
     119             :     };
     120             : 
     121             :     void SimElecBaseboard(
     122             :         EnergyPlusData &state, std::string const &EquipName, int const ZoneNum, bool const FirstHVACIteration, Real64 &PowerMet, int &CompIndex);
     123             : 
     124             :     void GetElectricBaseboardInput(EnergyPlusData &state);
     125             : 
     126             :     void InitElectricBaseboard(EnergyPlusData &state, int const BaseboardNum, int const ControlledZoneNum, bool const FirstHVACIteration);
     127             : 
     128             :     void SizeElectricBaseboard(EnergyPlusData &state, int const BaseboardNum);
     129             : 
     130             :     void CalcElectricBaseboard(EnergyPlusData &state, int const BaseboardNum, int const ControlledZoneNum);
     131             : 
     132             :     void UpdateElectricBaseboardOff(Real64 &LoadMet,
     133             :                                     Real64 &QBBCap,
     134             :                                     Real64 &RadHeat,
     135             :                                     Real64 &QBBElecRadSrc,
     136             :                                     Real64 &ElecUseRate,
     137             :                                     Real64 &AirOutletTemp,
     138             :                                     Real64 const AirInletTemp);
     139             : 
     140             :     void UpdateElectricBaseboardOn(
     141             :         Real64 &AirOutletTemp, Real64 &ElecUseRate, Real64 const AirInletTemp, Real64 const QBBCap, Real64 const CapacitanceAir, Real64 const Effic);
     142             : 
     143             :     void UpdateElectricBaseboard(EnergyPlusData &state, int const BaseboardNum);
     144             : 
     145             :     void UpdateBBElecRadSourceValAvg(EnergyPlusData &state, bool &ElecBaseboardSysOn); // .TRUE. if the radiant system has run this zone time step
     146             : 
     147             :     void DistributeBBElecRadGains(EnergyPlusData &state);
     148             : 
     149             :     void ReportElectricBaseboard(EnergyPlusData &state, int const BaseboardNum);
     150             : 
     151             : } // namespace ElectricBaseboardRadiator
     152             : 
     153             : struct ElectricBaseboardRadiatorData : BaseGlobalStruct
     154             : {
     155             :     std::string const cCMO_BBRadiator_Electric = "ZoneHVAC:Baseboard:RadiantConvective:Electric";
     156             : 
     157             :     // Object Data
     158             :     int NumElecBaseboards = 0;
     159             :     Array1D<ElectricBaseboardRadiator::ElecBaseboardParams> ElecBaseboard;
     160             :     Array1D<ElectricBaseboardRadiator::ElecBaseboardNumericFieldData> ElecBaseboardNumericFields;
     161             :     bool GetInputFlag = true; // One time get input flag
     162             : 
     163         796 :     void init_state([[maybe_unused]] EnergyPlusData &state) override
     164             :     {
     165         796 :     }
     166             : 
     167           0 :     void clear_state() override
     168             :     {
     169           0 :         this->NumElecBaseboards = 0;
     170           0 :         this->GetInputFlag = true;
     171           0 :         this->ElecBaseboard.clear();
     172           0 :         this->ElecBaseboardNumericFields.clear();
     173           0 :     }
     174             : };
     175             : 
     176             : } // namespace EnergyPlus
     177             : 
     178             : #endif

Generated by: LCOV version 1.14