LCOV - code coverage report
Current view: top level - EnergyPlus/AirflowNetwork/src - Properties.cpp (source / functions) Coverage Total Hit
Test: lcov.output.filtered Lines: 100.0 % 56 56
Test Date: 2025-05-22 16:09:37 Functions: 100.0 % 8 8

            Line data    Source code
       1              : // EnergyPlus, Copyright (c) 1996-2025, The Board of Trustees of the University of Illinois,
       2              : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3              : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4              : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5              : // contributors. All rights reserved.
       6              : //
       7              : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8              : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9              : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10              : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11              : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12              : //
      13              : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14              : // provided that the following conditions are met:
      15              : //
      16              : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17              : //     conditions and the following disclaimer.
      18              : //
      19              : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20              : //     conditions and the following disclaimer in the documentation and/or other materials
      21              : //     provided with the distribution.
      22              : //
      23              : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24              : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25              : //     used to endorse or promote products derived from this software without specific prior
      26              : //     written permission.
      27              : //
      28              : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29              : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30              : //     reference solely to the software portion of its product, Licensee must refer to the
      31              : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32              : //     obtained under this License and may not use a different name for the software. Except as
      33              : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34              : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35              : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36              : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37              : //
      38              : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39              : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40              : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41              : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42              : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43              : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44              : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45              : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46              : // POSSIBILITY OF SUCH DAMAGE.
      47              : 
      48              : #include "AirflowNetwork/Properties.hpp"
      49              : #include <EnergyPlus/Data/EnergyPlusData.hh>
      50              : #include <EnergyPlus/General.hh>
      51              : 
      52              : namespace EnergyPlus {
      53              : 
      54              : namespace AirflowNetwork {
      55              : 
      56          315 :     AirState::AirState(Real64 const density)
      57          315 :         : temperature(20.0), humidity_ratio(0.0), density(density), sqrt_density(sqrt(density)), viscosity(AIRDYNAMICVISCOSITY_CONSTEXPR(20.0))
      58              :     {
      59          315 :     }
      60              : 
      61            8 :     AirState::AirState()
      62            8 :         : temperature(20.0), humidity_ratio(0.0), density(AIRDENSITY_CONSTEXPR(101325.0, 20.0, 0.0)),
      63            8 :           sqrt_density(std::sqrt(AIRDENSITY_CONSTEXPR(101325.0, 20.0, 0.0))), viscosity(AIRDYNAMICVISCOSITY_CONSTEXPR(20.0))
      64              :     {
      65            8 :     }
      66              : 
      67      5299181 :     Real64 AirProperties::density(Real64 P, // Barometric pressure
      68              :                                   Real64 T, // Temperature in Celsius
      69              :                                   Real64 W  // Humidity ratio
      70              : 
      71              :     )
      72              :     {
      73      5299181 :         return Psychrometrics::PsyRhoAirFnPbTdbW(m_state, P, T, W);
      74              :     }
      75              : 
      76       798713 :     Real64 AirProperties::thermal_conductivity(Real64 T // Temperature in Celsius
      77              :     )
      78              :     {
      79              :         // Dry air thermal conductivity {W/m-K}
      80              :         // Correlated over the range -20C to 70C
      81              :         // Reference Cengel & Ghajar, Heat and Mass Transfer. 5th ed.
      82              : 
      83       798713 :         Real64 const LowerLimit = -20;
      84       798713 :         Real64 const UpperLimit = 70;
      85              : 
      86       798713 :         Real64 const a = 0.02364;
      87       798713 :         Real64 const b = 0.0000754772569209165;
      88       798713 :         Real64 const c = -2.40977632412045e-8;
      89              : 
      90       798713 :         if (T < LowerLimit) {
      91            1 :             if (lowerLimitErrIdx == 0) {
      92            3 :                 ShowWarningMessage(m_state, "Air temperature below lower limit of -20C for conductivity calculation");
      93              :             }
      94            7 :             ShowRecurringWarningErrorAtEnd(m_state,
      95            2 :                                            format("Air temperature below lower limit of -20C for conductivity calculation. Air temperature of {:.1R} "
      96              :                                                   "used for conductivity calculation.",
      97              :                                                   LowerLimit),
      98            1 :                                            lowerLimitErrIdx);
      99            1 :             T = LowerLimit;
     100       798712 :         } else if (T > UpperLimit) {
     101            1 :             if (upperLimitErrIdx == 0) {
     102            3 :                 ShowWarningMessage(m_state, "Air temperature above upper limit of 70C for conductivity calculation");
     103              :             }
     104            7 :             ShowRecurringWarningErrorAtEnd(m_state,
     105            2 :                                            format("Air temperature above upper limit of 70C for conductivity calculation. Air temperature of {:.1R} "
     106              :                                                   "used for conductivity calculation.",
     107              :                                                   UpperLimit),
     108            1 :                                            upperLimitErrIdx);
     109            1 :             T = UpperLimit;
     110              :         }
     111              : 
     112      1597426 :         return a + b * T + c * pow_2(T);
     113              :     }
     114              : 
     115       798748 :     Real64 AirProperties::dynamic_viscosity(Real64 T // Temperature in Celsius
     116              :     )
     117              :     {
     118       798748 :         return 1.71432e-5 + 4.828e-8 * T;
     119              :     }
     120              : 
     121       798702 :     Real64 AirProperties::kinematic_viscosity(Real64 P, // Barometric pressure
     122              :                                               Real64 T, // Temperature in Celsius
     123              :                                               Real64 W  // Humidity ratio
     124              : 
     125              :     )
     126              :     {
     127              :         // Dry air kinematic viscosity {m2/s}
     128              :         // Correlated over the range -20C to 70C
     129              :         // Reference Cengel & Ghajar, Heat and Mass Transfer. 5th ed.
     130              : 
     131       798702 :         Real64 const LowerLimit = -20;
     132       798702 :         Real64 const UpperLimit = 70;
     133              : 
     134       798702 :         if (T < LowerLimit) {
     135            1 :             T = LowerLimit;
     136       798701 :         } else if (T > UpperLimit) {
     137            1 :             T = UpperLimit;
     138              :         }
     139              : 
     140       798702 :         return dynamic_viscosity(T) / Psychrometrics::PsyRhoAirFnPbTdbW(m_state, P, T, W);
     141              :     }
     142              : 
     143       399359 :     Real64 AirProperties::thermal_diffusivity(Real64 P, // Barometric pressure
     144              :                                               Real64 T, // Temperature in Celsius
     145              :                                               Real64 W  // Humidity ratio
     146              :     )
     147              :     {
     148              :         // Dry air thermal diffusivity {-}
     149              :         // Correlated over the range -20C to 70C
     150              :         // Reference Cengel & Ghajar, Heat and Mass Transfer. 5th ed.
     151              : 
     152       399359 :         Real64 const LowerLimit = -20;
     153       399359 :         Real64 const UpperLimit = 70;
     154              : 
     155       399359 :         if (T < LowerLimit) {
     156            1 :             T = LowerLimit;
     157       399358 :         } else if (T > UpperLimit) {
     158            1 :             T = UpperLimit;
     159              :         }
     160              : 
     161       399359 :         return thermal_conductivity(T) / (AIRCP(W) * Psychrometrics::PsyRhoAirFnPbTdbW(m_state, P, T, W));
     162              :     }
     163              : 
     164       399351 :     Real64 AirProperties::prandtl_number(Real64 P, // Barometric pressure
     165              :                                          Real64 T, // Temperature in Celsius
     166              :                                          Real64 W  // Humidity ratio
     167              :     )
     168              :     {
     169              :         // Dry air Prandtl number {-}
     170              :         // Correlated over the range -20C to 70C
     171              :         // Reference Cengel & Ghajar, Heat and Mass Transfer. 5th ed.
     172              : 
     173       399351 :         Real64 const LowerLimit = -20;
     174       399351 :         Real64 const UpperLimit = 70;
     175              : 
     176       399351 :         if (T < LowerLimit) {
     177            1 :             T = LowerLimit;
     178       399350 :         } else if (T > UpperLimit) {
     179            1 :             T = UpperLimit;
     180              :         }
     181              : 
     182       399351 :         return kinematic_viscosity(P, T, W) / thermal_diffusivity(P, T, W);
     183              :     }
     184              : 
     185              : } // namespace AirflowNetwork
     186              : 
     187              : } // namespace EnergyPlus
        

Generated by: LCOV version 2.0-1