LCOV - code coverage report
Current view: top level - EnergyPlus - HeatPumpWaterToWaterSimple.hh (source / functions) Coverage Total Hit
Test: lcov.output.filtered Lines: 100.0 % 26 26
Test Date: 2025-05-22 16:09:37 Functions: 100.0 % 5 5

            Line data    Source code
       1              : // EnergyPlus, Copyright (c) 1996-2025, The Board of Trustees of the University of Illinois,
       2              : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3              : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4              : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5              : // contributors. All rights reserved.
       6              : //
       7              : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8              : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9              : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10              : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11              : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12              : //
      13              : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14              : // provided that the following conditions are met:
      15              : //
      16              : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17              : //     conditions and the following disclaimer.
      18              : //
      19              : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20              : //     conditions and the following disclaimer in the documentation and/or other materials
      21              : //     provided with the distribution.
      22              : //
      23              : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24              : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25              : //     used to endorse or promote products derived from this software without specific prior
      26              : //     written permission.
      27              : //
      28              : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29              : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30              : //     reference solely to the software portion of its product, Licensee must refer to the
      31              : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32              : //     obtained under this License and may not use a different name for the software. Except as
      33              : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34              : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35              : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36              : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37              : //
      38              : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39              : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40              : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41              : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42              : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43              : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44              : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45              : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46              : // POSSIBILITY OF SUCH DAMAGE.
      47              : 
      48              : #ifndef HeatPumpWaterToWaterSimple_hh_INCLUDED
      49              : #define HeatPumpWaterToWaterSimple_hh_INCLUDED
      50              : 
      51              : // ObjexxFCL Headers
      52              : #include <ObjexxFCL/Array1D.hh>
      53              : 
      54              : // EnergyPlus Headers
      55              : #include <EnergyPlus/Data/BaseData.hh>
      56              : #include <EnergyPlus/DataGlobals.hh>
      57              : #include <EnergyPlus/EnergyPlus.hh>
      58              : #include <EnergyPlus/PlantComponent.hh>
      59              : 
      60              : namespace EnergyPlus {
      61              : 
      62              : // Forward declarations
      63              : struct EnergyPlusData;
      64              : 
      65              : namespace HeatPumpWaterToWaterSimple {
      66              : 
      67              :     struct GshpSpecs : public PlantComponent
      68              :     {
      69              :         // Members
      70              :         std::string Name;                       // user identifier
      71              :         bool checkEquipName;                    // name check flag
      72              :         DataPlant::PlantEquipmentType WWHPType; // equipment type num
      73              :         bool Available;                         // need an array of logicals--load identifiers of available equipment
      74              :         bool ON;                                // simulate the machine at it's operating part load ratio
      75              :         bool IsOn;                              // flag that the heat pump is ON during current time step
      76              :         bool MustRun;                           // flag that the heat pump is MUST RUN during current time step
      77              :         Real64 SourceSideDesignMassFlow;        // Design flow rate (kg/s)
      78              : 
      79              :         Real64 LoadSideDesignMassFlow; // Design flow rate (kg/s)
      80              : 
      81              :         Real64 RatedLoadVolFlowCool;             // Rated Cooling Load Side Volumetric Flow Rate [m3/s]
      82              :         bool ratedLoadVolFlowCoolWasAutoSized;   // true if RatedSourceVolFlowCool was autosize on input
      83              :         Real64 RatedSourceVolFlowCool;           // Rated Cooling Source Side Volumetric Flow Rate [m3/s]
      84              :         bool ratedSourceVolFlowCoolWasAutoSized; // true if RatedSourceVolFlowCool was autosize on input
      85              :         Real64 RatedCapCool;                     // Rated Cooling Capacity [W]
      86              :         bool ratedCapCoolWasAutoSized;           // true if RatedCapCool was autosize on input
      87              :         Real64 RatedPowerCool;                   // Rated Cooling Power Consumption[W]
      88              :         bool ratedPowerCoolWasAutoSized;         // ture if RatedPowerCool was autosize on input
      89              :         int CoolCapCurveIndex;                   // Index of the Cooling capacity performance curve
      90              :         int CoolPowCurveIndex;                   // Index of the Cooling power consumption curve
      91              :         int CoolCapNegativeCounter;              // Counter for number of times cooling capacity curve is <= 0.0
      92              :         int CoolCapNegativeIndex;                // Index for recurring warning message regarding cooling capacity curve is <= 0.0
      93              :         int CoolPowerNegativeCounter;            // Counter for number of times cooling power curve is <= 0.0
      94              :         int CoolPowerNegativeIndex;              // Index for recurring warning message regarding cooling power curve is <= 0.0
      95              :         Real64 RatedLoadVolFlowHeat;             // Rated Heating Load Side Volumetric Flow Rate [m3/s]
      96              :         bool ratedLoadVolFlowHeatWasAutoSized;   // true if RatedLoadVolFlowHeat was autosize on input
      97              :         Real64 RatedSourceVolFlowHeat;           // Rated Heating Source Side Volumetric Flow Rate [m3/s]
      98              :         bool ratedSourceVolFlowHeatWasAutoSized; // true if RatedSourceVolFlowHeat was autosize on input
      99              :         Real64 RatedCapHeat;                     // Rated Heating Capacity [W]
     100              :         bool ratedCapHeatWasAutoSized;           // true if RatedCapHeat was autosize on input
     101              :         Real64 RatedPowerHeat;                   // Rated Heating Compressor Power[W]
     102              :         bool ratedPowerHeatWasAutoSized;         // true if RatedPowerHeat was autosize on input
     103              :         int HeatCapCurveIndex;                   // Index of the Heating capacity performance curve
     104              :         int HeatPowCurveIndex;                   // Index of the Heating power consumption curve
     105              :         int LoadSideInletNodeNum;                // Load Side Inlet Node
     106              :         int LoadSideOutletNodeNum;               // Load Side Outlet Node
     107              :         int SourceSideInletNodeNum;              // Source Side Inlet Node
     108              :         int SourceSideOutletNodeNum;             // Source Side Outlet Node
     109              :         int HeatCapNegativeCounter;              // Counter for number of times heating capacity curve is <= 0.0
     110              :         int HeatCapNegativeIndex;                // Index for recurring warning message regarding heating capacity curve is <= 0.0
     111              :         int HeatPowerNegativeCounter;            // Counter for number of times heating power curve is <= 0.0
     112              :         int HeatPowerNegativeIndex;              // Index for recurring warning message regarding heating power curve is <= 0.0
     113              :         // loop topology variables
     114              :         PlantLocation SourcePlantLoc; // source side plant loop component location
     115              :         PlantLocation LoadPlantLoc;   // load side plant loop component location
     116              :         int CondMassFlowIndex;        // index for criteria in PullCompInterconnectTrigger
     117              :         Real64 refCOP;                // reference COP used for sizing reference power, user input
     118              :         Real64 sizFac;                // component level sizing factor, user input
     119              :         std::string companionName;    // name of companion GSHP
     120              :         int companionIndex;           // index in GSHP structure for companion heat pump
     121              :         bool companionIdentified;     // true if this GSHP has found its companion heat pump
     122              : 
     123              :         // Report variables
     124              :         Real64 reportPower;                  // Power Consumption [W]
     125              :         Real64 reportEnergy;                 // Energy Consumption [J]
     126              :         Real64 reportQLoad;                  // Load Side Heat Transfer Rate [W]
     127              :         Real64 reportQLoadEnergy;            // Load Side Heat Transfer [J]
     128              :         Real64 reportQSource;                // Source Side Heat Transfer Rate [W]
     129              :         Real64 reportQSourceEnergy;          // Source Side Heat Transfer [J]
     130              :         Real64 reportLoadSideMassFlowRate;   // Load side volumetric flow rate m3/s
     131              :         Real64 reportLoadSideInletTemp;      // Load Side outlet temperature degC
     132              :         Real64 reportLoadSideOutletTemp;     // Load Side outlet temperature degC
     133              :         Real64 reportSourceSideMassFlowRate; // Source side volumetric flow rate m3/s
     134              :         Real64 reportSourceSideInletTemp;    // Source Side outlet temperature degC
     135              :         Real64 reportSourceSideOutletTemp;   // Source Side outlet temperature degC
     136              : 
     137              :         // init flags
     138              :         bool MyPlantScanFlag;
     139              :         bool MyEnvrnFlag;
     140              : 
     141              :         bool myCoolingSizesReported;
     142              :         bool myHeatingSizesReported;
     143              : 
     144              :         // Default Constructor
     145            2 :         GshpSpecs()
     146            4 :             : checkEquipName(true), WWHPType(DataPlant::PlantEquipmentType::Invalid), Available(false), ON(false), IsOn(false), MustRun(false),
     147            2 :               SourceSideDesignMassFlow(0.0), LoadSideDesignMassFlow(0.0), RatedLoadVolFlowCool(0.0), ratedLoadVolFlowCoolWasAutoSized(false),
     148            2 :               RatedSourceVolFlowCool(0.0), ratedSourceVolFlowCoolWasAutoSized(false), RatedCapCool(0.0), ratedCapCoolWasAutoSized(false),
     149            2 :               RatedPowerCool(0.0), ratedPowerCoolWasAutoSized(false), CoolCapCurveIndex(0), CoolPowCurveIndex(0), CoolCapNegativeCounter(0),
     150            2 :               CoolCapNegativeIndex(0), CoolPowerNegativeCounter(0), CoolPowerNegativeIndex(0), RatedLoadVolFlowHeat(0.0),
     151            2 :               ratedLoadVolFlowHeatWasAutoSized(false), RatedSourceVolFlowHeat(0.0), ratedSourceVolFlowHeatWasAutoSized(false), RatedCapHeat(0.0),
     152            2 :               ratedCapHeatWasAutoSized(false), RatedPowerHeat(0.0), ratedPowerHeatWasAutoSized(false), HeatCapCurveIndex(0), HeatPowCurveIndex(0),
     153            2 :               LoadSideInletNodeNum(0), LoadSideOutletNodeNum(0), SourceSideInletNodeNum(0), SourceSideOutletNodeNum(0), HeatCapNegativeCounter(0),
     154            2 :               HeatCapNegativeIndex(0), HeatPowerNegativeCounter(0), HeatPowerNegativeIndex(0), SourcePlantLoc{}, LoadPlantLoc{}, CondMassFlowIndex(0),
     155            4 :               refCOP(0.0), sizFac(0.0), companionIndex(0), companionIdentified(false), reportPower(0.0), reportEnergy(0.0), reportQLoad(0.0),
     156            2 :               reportQLoadEnergy(0.0), reportQSource(0.0), reportQSourceEnergy(0.0), reportLoadSideMassFlowRate(0.0), reportLoadSideInletTemp(0.0),
     157            2 :               reportLoadSideOutletTemp(0.0), reportSourceSideMassFlowRate(0.0), reportSourceSideInletTemp(0.0), reportSourceSideOutletTemp(0.0),
     158            4 :               MyPlantScanFlag(true), MyEnvrnFlag(true), myCoolingSizesReported(false), myHeatingSizesReported(false)
     159              :         {
     160            2 :         }
     161              : 
     162            2 :         virtual ~GshpSpecs() = default;
     163              : 
     164              :         static GshpSpecs *factory(EnergyPlusData &state, DataPlant::PlantEquipmentType wwhp_type, std::string_view eir_wwhp_name);
     165              : 
     166              :         static void GetWatertoWaterHPInput(EnergyPlusData &state);
     167              : 
     168              :         void simulate([[maybe_unused]] EnergyPlusData &state,
     169              :                       const PlantLocation &calledFromLocation,
     170              :                       bool FirstHVACIteration,
     171              :                       Real64 &CurLoad,
     172              :                       bool RunFlag) override;
     173              : 
     174              :         void getDesignCapacities(
     175              :             EnergyPlusData &state, const PlantLocation &calledFromLocation, Real64 &MaxLoad, Real64 &MinLoad, Real64 &OptLoad) override;
     176              : 
     177              :         void getSizingFactor(Real64 &sizingFactor) override;
     178              : 
     179              :         void InitWatertoWaterHP(EnergyPlusData &state,
     180              :                                 DataPlant::PlantEquipmentType GSHPTypeNum, // Type of GSHP
     181              :                                 std::string const &GSHPName,               // User Specified Name of GSHP
     182              :                                 bool FirstHVACIteration,
     183              :                                 Real64 MyLoad // Demand Load
     184              :         );
     185              : 
     186              :         void sizeCoolingWaterToWaterHP(EnergyPlusData &state);
     187              : 
     188              :         void sizeHeatingWaterToWaterHP(EnergyPlusData &state);
     189              : 
     190              :         void CalcWatertoWaterHPCooling(EnergyPlusData &state, Real64 MyLoad); // Operating Load
     191              : 
     192              :         void CalcWatertoWaterHPHeating(EnergyPlusData &state, Real64 MyLoad); // Operating Load
     193              : 
     194              :         void UpdateGSHPRecords(EnergyPlusData &state);
     195              : 
     196              :         void onInitLoopEquip(EnergyPlusData &state, const PlantLocation &calledFromLocation) override;
     197              : 
     198              :         void oneTimeInit(EnergyPlusData &state) override;
     199              : 
     200              :         void oneTimeInit_new(EnergyPlusData &state) override;
     201              :     };
     202              : 
     203              : } // namespace HeatPumpWaterToWaterSimple
     204              : 
     205              : struct HeatPumpWaterToWaterSimpleData : BaseGlobalStruct
     206              : {
     207              : 
     208              :     int NumGSHPs = 0;
     209              :     bool GetInputFlag = true;
     210              :     Array1D<HeatPumpWaterToWaterSimple::GshpSpecs> GSHP;
     211              :     std::unordered_map<std::string, std::string> HeatPumpWaterUniqueNames;
     212              : 
     213         2126 :     void init_constant_state([[maybe_unused]] EnergyPlusData &state) override
     214              :     {
     215         2126 :     }
     216              : 
     217         1152 :     void init_state([[maybe_unused]] EnergyPlusData &state) override
     218              :     {
     219         1152 :     }
     220              : 
     221         2100 :     void clear_state() override
     222              :     {
     223         2100 :         this->NumGSHPs = 0;
     224         2100 :         this->GetInputFlag = true;
     225         2100 :         this->GSHP.deallocate();
     226         2100 :         this->HeatPumpWaterUniqueNames.clear();
     227         2100 :     }
     228              : };
     229              : 
     230              : } // namespace EnergyPlus
     231              : 
     232              : #endif
        

Generated by: LCOV version 2.0-1