LCOV - code coverage report
Current view: top level - EnergyPlus/Plant - Branch.cc (source / functions) Coverage Total Hit
Test: lcov.output.filtered Lines: 100.0 % 11 11
Test Date: 2025-05-22 16:09:37 Functions: 100.0 % 1 1

            Line data    Source code
       1              : // EnergyPlus, Copyright (c) 1996-2025, The Board of Trustees of the University of Illinois,
       2              : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3              : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4              : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5              : // contributors. All rights reserved.
       6              : //
       7              : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8              : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9              : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10              : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11              : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12              : //
      13              : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14              : // provided that the following conditions are met:
      15              : //
      16              : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17              : //     conditions and the following disclaimer.
      18              : //
      19              : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20              : //     conditions and the following disclaimer in the documentation and/or other materials
      21              : //     provided with the distribution.
      22              : //
      23              : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24              : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25              : //     used to endorse or promote products derived from this software without specific prior
      26              : //     written permission.
      27              : //
      28              : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29              : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30              : //     reference solely to the software portion of its product, Licensee must refer to the
      31              : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32              : //     obtained under this License and may not use a different name for the software. Except as
      33              : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34              : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35              : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36              : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37              : //
      38              : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39              : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40              : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41              : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42              : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43              : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44              : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45              : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46              : // POSSIBILITY OF SUCH DAMAGE.
      47              : 
      48              : #include <EnergyPlus/Data/EnergyPlusData.hh>
      49              : #include <EnergyPlus/DataBranchAirLoopPlant.hh>
      50              : #include <EnergyPlus/DataLoopNode.hh>
      51              : #include <EnergyPlus/Plant/Branch.hh>
      52              : #include <EnergyPlus/PlantUtilities.hh>
      53              : 
      54              : namespace EnergyPlus {
      55              : namespace DataPlant {
      56              : 
      57       485989 :     Real64 BranchData::DetermineBranchFlowRequest(EnergyPlusData &state)
      58              :     {
      59              : 
      60              :         // SUBROUTINE INFORMATION:
      61              :         //       AUTHOR         Edwin Lee
      62              :         //       DATE WRITTEN   September 2010
      63              :         //       MODIFIED       na
      64              :         //       RE-ENGINEERED  na
      65              : 
      66              :         // PURPOSE OF THIS SUBROUTINE:
      67              :         // This routine will analyze the given branch and determine the representative
      68              :         //  flow request.
      69              : 
      70              :         // METHODOLOGY EMPLOYED:
      71              :         // Several possibilities are available.  In any case, the request is constrained to within
      72              :         //  branch outlet min/max avail.  This assumes that the component flow routines will properly
      73              :         //  propagate the min/max avail down the branch.
      74              :         // Some possibilities for flow request are:
      75              :         //  1) take the outlet flow rate -- assumes that the last component wins
      76              :         //  2) take the inlet flow rate request -- assumes that the request is propagated up and is good
      77              :         //  3) take the maximum request
      78              :         //  4) move down the loop and take the maximum "non-load-range-based" request within min/max avail bounds
      79              :         //     This assumes that load range based should not request flow for load-rejection purposes, and we
      80              :         //     should only "respond" to other component types.
      81              : 
      82       485989 :         int const BranchInletNodeNum = this->NodeNumIn;
      83       485989 :         int const BranchOutletNodeNum = this->NodeNumOut;
      84       485989 :         Real64 OverallFlowRequest = 0.0;
      85              : 
      86       485989 :         if (this->controlType != DataBranchAirLoopPlant::ControlType::SeriesActive) {
      87       485988 :             OverallFlowRequest = state.dataLoopNodes->Node(BranchInletNodeNum).MassFlowRateRequest;
      88              :         } else { // is series active, so take largest request of all the component inlet nodes
      89            3 :             for (int CompCounter = 1; CompCounter <= this->TotalComponents; ++CompCounter) {
      90            2 :                 int const CompInletNode = this->Comp(CompCounter).NodeNumIn;
      91            2 :                 OverallFlowRequest = max(OverallFlowRequest, state.dataLoopNodes->Node(CompInletNode).MassFlowRateRequest);
      92              :             }
      93              :         }
      94              : 
      95              :         //~ Now use a worker to bound the value to outlet min/max avail
      96       485989 :         OverallFlowRequest = PlantUtilities::BoundValueToNodeMinMaxAvail(state, OverallFlowRequest, BranchOutletNodeNum);
      97              : 
      98       485989 :         return OverallFlowRequest;
      99              :     }
     100              : 
     101              : } // namespace DataPlant
     102              : } // namespace EnergyPlus
        

Generated by: LCOV version 2.0-1