Line data Source code
1 : // EnergyPlus, Copyright (c) 1996-2025, The Board of Trustees of the University of Illinois,
2 : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
3 : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
4 : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
5 : // contributors. All rights reserved.
6 : //
7 : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
8 : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
9 : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
10 : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
11 : // derivative works, and perform publicly and display publicly, and to permit others to do so.
12 : //
13 : // Redistribution and use in source and binary forms, with or without modification, are permitted
14 : // provided that the following conditions are met:
15 : //
16 : // (1) Redistributions of source code must retain the above copyright notice, this list of
17 : // conditions and the following disclaimer.
18 : //
19 : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
20 : // conditions and the following disclaimer in the documentation and/or other materials
21 : // provided with the distribution.
22 : //
23 : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
24 : // the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
25 : // used to endorse or promote products derived from this software without specific prior
26 : // written permission.
27 : //
28 : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
29 : // without changes from the version obtained under this License, or (ii) Licensee makes a
30 : // reference solely to the software portion of its product, Licensee must refer to the
31 : // software as "EnergyPlus version X" software, where "X" is the version number Licensee
32 : // obtained under this License and may not use a different name for the software. Except as
33 : // specifically required in this Section (4), Licensee shall not use in a company name, a
34 : // product name, in advertising, publicity, or other promotional activities any name, trade
35 : // name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
36 : // similar designation, without the U.S. Department of Energy's prior written consent.
37 : //
38 : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
39 : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
40 : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
41 : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
42 : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
43 : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
44 : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
45 : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
46 : // POSSIBILITY OF SUCH DAMAGE.
47 :
48 : #include <EnergyPlus/Data/EnergyPlusData.hh>
49 : #include <EnergyPlus/DataStringGlobals.hh>
50 : #include <EnergyPlus/PluginManager.hh>
51 : #include <EnergyPlus/UtilityRoutines.hh>
52 : #include <EnergyPlus/api/EnergyPlusPgm.hh>
53 : #include <EnergyPlus/api/runtime.h>
54 :
55 : // disabling "maybe unused" warnings for all the API functions so the IDE isn't lit up with messages
56 : #pragma clang diagnostic push
57 : #pragma ide diagnostic ignored "OCUnusedGlobalDeclarationInspection"
58 :
59 24 : int energyplus(EnergyPlusState state, int argc, const char *argv[])
60 : {
61 : // argv[0] = "energyplus";
62 : // argv[1] = "-d";
63 : // argv[2] = workingPath.string().c_str();
64 : // argv[3] = "-w";
65 : // argv[4] = epcomp->weatherFilePath.c_str();
66 : // argv[5] = "-i";
67 : // argv[6] = epcomp->iddPath.c_str();
68 : // argv[7] = epcomp->idfInputPath.c_str();
69 24 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
70 24 : if (!thisState->ready) {
71 1 : std::cerr << "Attempted to re-run EnergyPlus using a state that was not yet cleared, call stateReset() on this instance and try again\n";
72 1 : return 1;
73 : }
74 23 : thisState->ready = false;
75 46 : std::vector<std::string> args(argv, std::next(argv, static_cast<std::ptrdiff_t>(argc)));
76 23 : return runEnergyPlusAsLibrary(*thisState, args);
77 23 : }
78 :
79 1 : void stopSimulation(EnergyPlusState state)
80 : {
81 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
82 1 : thisState->dataGlobal->stopSimulation = true;
83 1 : }
84 :
85 6 : void setConsoleOutputState(EnergyPlusState state, int outputStatus)
86 : {
87 6 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
88 6 : thisState->dataGlobal->printConsoleOutput = (outputStatus != 0);
89 6 : }
90 :
91 15 : void setEnergyPlusRootDirectory(EnergyPlusState state, const char *path)
92 : {
93 15 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
94 15 : thisState->dataGlobal->installRootOverride = true;
95 15 : thisState->dataStrGlobals->exeDirectoryPath = fs::path(path);
96 15 : }
97 :
98 2 : void issueWarning(EnergyPlusState state, const char *message)
99 : {
100 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
101 4 : ShowWarningError(*thisState, message);
102 2 : }
103 2 : void issueSevere(EnergyPlusState state, const char *message)
104 : {
105 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
106 4 : ShowSevereError(*thisState, message);
107 2 : }
108 2 : void issueText(EnergyPlusState state, const char *message)
109 : {
110 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
111 4 : ShowContinueError(*thisState, message);
112 2 : }
113 :
114 0 : void registerProgressCallback([[maybe_unused]] EnergyPlusState state, std::function<void(int const)> f)
115 : {
116 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
117 0 : thisState->dataGlobal->progressCallback = std::move(f);
118 0 : }
119 :
120 6 : void registerProgressCallback(EnergyPlusState state, void (*f)(int const))
121 : {
122 6 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
123 6 : thisState->dataGlobal->progressCallback = f;
124 6 : }
125 :
126 2 : void registerStdOutCallback([[maybe_unused]] EnergyPlusState state, std::function<void(const std::string &)> f)
127 : {
128 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
129 2 : thisState->dataGlobal->messageCallback = std::move(f);
130 2 : }
131 :
132 2 : void registerStdOutCallback(EnergyPlusState state, void (*f)(const char *))
133 : {
134 : // Extra lamba needed to go from `const std::string&` to `const char *`
135 83 : const auto stdf = [f](const std::string &message) { f(message.c_str()); };
136 2 : registerStdOutCallback(state, std::function<void(const std::string &)>(stdf));
137 2 : }
138 :
139 0 : void registerExternalHVACManager(EnergyPlusState state, std::function<void(EnergyPlusState)> f)
140 : {
141 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
142 0 : thisState->dataGlobal->externalHVACManager = std::move(f);
143 0 : }
144 :
145 1 : void registerExternalHVACManager(EnergyPlusState state, void (*f)(EnergyPlusState))
146 : {
147 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
148 1 : thisState->dataGlobal->externalHVACManager = f;
149 1 : }
150 :
151 0 : void callbackBeginNewEnvironment(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
152 : {
153 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
154 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginNewEnvironment, f);
155 0 : }
156 :
157 7 : void callbackBeginNewEnvironment(EnergyPlusState state, void (*f)(EnergyPlusState))
158 : {
159 7 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
160 7 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginNewEnvironment, f);
161 7 : }
162 :
163 0 : void callbackBeginZoneTimestepBeforeSetCurrentWeather(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
164 : {
165 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
166 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepBeforeSetCurrentWeather, f);
167 0 : }
168 :
169 0 : void callbackBeginZoneTimestepBeforeSetCurrentWeather(EnergyPlusState state, void (*f)(EnergyPlusState))
170 : {
171 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
172 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepBeforeSetCurrentWeather, f);
173 0 : }
174 :
175 0 : void callbackAfterNewEnvironmentWarmupComplete(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
176 : {
177 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
178 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginNewEnvironmentAfterWarmUp, f);
179 0 : }
180 :
181 2 : void callbackAfterNewEnvironmentWarmupComplete(EnergyPlusState state, void (*f)(EnergyPlusState))
182 : {
183 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
184 2 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginNewEnvironmentAfterWarmUp, f);
185 2 : }
186 :
187 0 : void callbackBeginZoneTimeStepBeforeInitHeatBalance(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
188 : {
189 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
190 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepBeforeInitHeatBalance, f);
191 0 : }
192 :
193 1 : void callbackBeginZoneTimeStepBeforeInitHeatBalance(EnergyPlusState state, void (*f)(EnergyPlusState))
194 : {
195 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
196 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepBeforeInitHeatBalance, f);
197 1 : }
198 :
199 0 : void callbackBeginZoneTimeStepAfterInitHeatBalance(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
200 : {
201 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
202 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepAfterInitHeatBalance, f);
203 0 : }
204 :
205 1 : void callbackBeginZoneTimeStepAfterInitHeatBalance(EnergyPlusState state, void (*f)(EnergyPlusState))
206 : {
207 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
208 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginZoneTimestepAfterInitHeatBalance, f);
209 1 : }
210 :
211 0 : void callbackBeginTimeStepBeforePredictor(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
212 : {
213 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
214 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginTimestepBeforePredictor, f);
215 0 : }
216 :
217 2 : void callbackBeginTimeStepBeforePredictor(EnergyPlusState state, void (*f)(EnergyPlusState))
218 : {
219 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
220 2 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeginTimestepBeforePredictor, f);
221 2 : }
222 :
223 0 : void callbackAfterPredictorBeforeHVACManagers(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
224 : {
225 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
226 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeforeHVACManagers, f);
227 0 : }
228 :
229 1 : void callbackAfterPredictorBeforeHVACManagers(EnergyPlusState state, void (*f)(EnergyPlusState))
230 : {
231 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
232 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::BeforeHVACManagers, f);
233 1 : }
234 :
235 0 : void callbackAfterPredictorAfterHVACManagers(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
236 : {
237 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
238 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::AfterHVACManagers, f);
239 0 : }
240 :
241 1 : void callbackAfterPredictorAfterHVACManagers(EnergyPlusState state, void (*f)(EnergyPlusState))
242 : {
243 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
244 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::AfterHVACManagers, f);
245 1 : }
246 :
247 0 : void callbackInsideSystemIterationLoop(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
248 : {
249 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
250 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::HVACIterationLoop, f);
251 0 : }
252 :
253 1 : void callbackInsideSystemIterationLoop(EnergyPlusState state, void (*f)(EnergyPlusState))
254 : {
255 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
256 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::HVACIterationLoop, f);
257 1 : }
258 :
259 0 : void callbackEndOfZoneTimeStepBeforeZoneReporting(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
260 : {
261 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
262 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndZoneTimestepBeforeZoneReporting, f);
263 0 : }
264 :
265 1 : void callbackEndOfZoneTimeStepBeforeZoneReporting(EnergyPlusState state, void (*f)(EnergyPlusState))
266 : {
267 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
268 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndZoneTimestepBeforeZoneReporting, f);
269 1 : }
270 :
271 0 : void callbackEndOfZoneTimeStepAfterZoneReporting(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
272 : {
273 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
274 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndZoneTimestepAfterZoneReporting, f);
275 0 : }
276 :
277 3 : void callbackEndOfZoneTimeStepAfterZoneReporting(EnergyPlusState state, void (*f)(EnergyPlusState))
278 : {
279 3 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
280 3 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndZoneTimestepAfterZoneReporting, f);
281 3 : }
282 :
283 0 : void callbackEndOfSystemTimeStepBeforeHVACReporting(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
284 : {
285 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
286 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndSystemTimestepBeforeHVACReporting, f);
287 0 : }
288 :
289 1 : void callbackEndOfSystemTimeStepBeforeHVACReporting(EnergyPlusState state, void (*f)(EnergyPlusState))
290 : {
291 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
292 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndSystemTimestepBeforeHVACReporting, f);
293 1 : }
294 :
295 0 : void callbackEndOfSystemTimeStepAfterHVACReporting(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
296 : {
297 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
298 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndSystemTimestepAfterHVACReporting, f);
299 0 : }
300 :
301 1 : void callbackEndOfSystemTimeStepAfterHVACReporting(EnergyPlusState state, void (*f)(EnergyPlusState))
302 : {
303 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
304 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::EndSystemTimestepAfterHVACReporting, f);
305 1 : }
306 :
307 0 : void callbackEndOfZoneSizing(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
308 : {
309 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
310 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::ZoneSizing, f);
311 0 : }
312 :
313 1 : void callbackEndOfZoneSizing(EnergyPlusState state, void (*f)(EnergyPlusState))
314 : {
315 1 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
316 1 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::ZoneSizing, f);
317 1 : }
318 :
319 0 : void callbackEndOfSystemSizing(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
320 : {
321 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
322 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::SystemSizing, f);
323 0 : }
324 :
325 2 : void callbackEndOfSystemSizing(EnergyPlusState state, void (*f)(EnergyPlusState))
326 : {
327 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
328 2 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::SystemSizing, f);
329 2 : }
330 :
331 0 : void callbackEndOfAfterComponentGetInput(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
332 : {
333 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
334 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::ComponentGetInput, f);
335 0 : }
336 :
337 2 : void callbackEndOfAfterComponentGetInput(EnergyPlusState state, void (*f)(EnergyPlusState))
338 : {
339 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
340 2 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::ComponentGetInput, f);
341 2 : }
342 :
343 0 : void callbackUserDefinedComponentModel(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f, const char *programNameInInputFile)
344 : {
345 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
346 0 : EnergyPlus::PluginManagement::registerUserDefinedCallback(*thisState, f, programNameInInputFile);
347 0 : }
348 :
349 2 : void callbackUserDefinedComponentModel(EnergyPlusState state, void (*f)(EnergyPlusState), const char *programNameInInputFile)
350 : {
351 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
352 2 : EnergyPlus::PluginManagement::registerUserDefinedCallback(*thisState, f, programNameInInputFile);
353 2 : }
354 :
355 0 : void callbackUnitarySystemSizing(EnergyPlusState state, std::function<void(EnergyPlusState)> const &f)
356 : {
357 0 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
358 0 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::UnitarySystemSizing, f);
359 0 : }
360 :
361 2 : void callbackUnitarySystemSizing(EnergyPlusState state, void (*f)(EnergyPlusState))
362 : {
363 2 : auto *thisState = reinterpret_cast<EnergyPlus::EnergyPlusData *>(state); // NOLINT(cppcoreguidelines-pro-type-reinterpret-cast)
364 2 : EnergyPlus::PluginManagement::registerNewCallback(*thisState, EnergyPlus::EMSManager::EMSCallFrom::UnitarySystemSizing, f);
365 2 : }