       1              : // EnergyPlus, Copyright (c) 1996-2025, The Board of Trustees of the University of Illinois,
       2              : // The Regents of the University of California, through Lawrence Berkeley National Laboratory
       3              : // (subject to receipt of any required approvals from the U.S. Dept. of Energy), Oak Ridge
       4              : // National Laboratory, managed by UT-Battelle, Alliance for Sustainable Energy, LLC, and other
       5              : // contributors. All rights reserved.
       6              : //
       7              : // NOTICE: This Software was developed under funding from the U.S. Department of Energy and the
       8              : // U.S. Government consequently retains certain rights. As such, the U.S. Government has been
       9              : // granted for itself and others acting on its behalf a paid-up, nonexclusive, irrevocable,
      10              : // worldwide license in the Software to reproduce, distribute copies to the public, prepare
      11              : // derivative works, and perform publicly and display publicly, and to permit others to do so.
      12              : //
      13              : // Redistribution and use in source and binary forms, with or without modification, are permitted
      14              : // provided that the following conditions are met:
      15              : //
      16              : // (1) Redistributions of source code must retain the above copyright notice, this list of
      17              : //     conditions and the following disclaimer.
      18              : //
      19              : // (2) Redistributions in binary form must reproduce the above copyright notice, this list of
      20              : //     conditions and the following disclaimer in the documentation and/or other materials
      21              : //     provided with the distribution.
      22              : //
      23              : // (3) Neither the name of the University of California, Lawrence Berkeley National Laboratory,
      24              : //     the University of Illinois, U.S. Dept. of Energy nor the names of its contributors may be
      25              : //     used to endorse or promote products derived from this software without specific prior
      26              : //     written permission.
      27              : //
      28              : // (4) Use of EnergyPlus(TM) Name. If Licensee (i) distributes the software in stand-alone form
      29              : //     without changes from the version obtained under this License, or (ii) Licensee makes a
      30              : //     reference solely to the software portion of its product, Licensee must refer to the
      31              : //     software as "EnergyPlus version X" software, where "X" is the version number Licensee
      32              : //     obtained under this License and may not use a different name for the software. Except as
      33              : //     specifically required in this Section (4), Licensee shall not use in a company name, a
      34              : //     product name, in advertising, publicity, or other promotional activities any name, trade
      35              : //     name, trademark, logo, or other designation of "EnergyPlus", "E+", "e+" or confusingly
      36              : //     similar designation, without the U.S. Department of Energy's prior written consent.
      37              : //
      38              : // THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR
      39              : // IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY
      40              : // AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
      41              : // CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
      42              : // CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
      43              : // SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
      44              : // THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
      45              : // OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
      46              : // POSSIBILITY OF SUCH DAMAGE.
      47              : 
      48              : #include <EnergyPlus/Autosizing/HeatingCapacitySizing.hh>
      49              : #include <EnergyPlus/CurveManager.hh>
      50              : #include <EnergyPlus/Data/EnergyPlusData.hh>
      51              : #include <EnergyPlus/DataEnvironment.hh>
      52              : #include <EnergyPlus/DataHVACGlobals.hh>
      53              : #include <EnergyPlus/Fans.hh>
      54              : #include <EnergyPlus/General.hh>
      55              : #include <EnergyPlus/GeneralRoutines.hh>
      56              : #include <EnergyPlus/Psychrometrics.hh>
      57              : #include <EnergyPlus/SimAirServingZones.hh>
      58              : #include <EnergyPlus/WeatherManager.hh>
      59              : 
      60              : namespace EnergyPlus {
      61              : 
      62         3764 : Real64 HeatingCapacitySizer::size(EnergyPlusData &state, Real64 _originalValue, bool &errorsFound)
      63              : {
      64         3764 :     if (!this->checkInitialized(state, errorsFound)) {
      65            0 :         return 0.0;
      66              :     }
      67         3764 :     this->preSize(state, _originalValue);
      68         3764 :     Real64 DesVolFlow = 0.0;
      69         3764 :     Real64 CoilInTemp = -999.0;
      70         3764 :     Real64 CoilInHumRat = -999.0;
      71         3764 :     Real64 CoilOutTemp = -999.0;
      72         3764 :     Real64 CoilOutHumRat = -999.0;
      73              : 
      74         3764 :     Real64 DXFlowPerCapMinRatio = 1.0;
      75         3764 :     Real64 DXFlowPerCapMaxRatio = 1.0;
      76         3764 :     Real64 NominalCapacityDes = 0.0;
      77         3764 :     Real64 DesMassFlow = 0.0;
      78         3764 :     Real64 DesCoilLoad = 0.0;
      79         3764 :     Real64 OutAirFrac = 0.0;
      80         3764 :     Real64 const CpAirStd = Psychrometrics::PsyCpAirFnW(0.0);
      81              : 
      82         3764 :     if (this->dataEMSOverrideON) {
      83            0 :         this->autoSizedValue = this->dataEMSOverride;
      84         3764 :     } else if (this->dataConstantUsedForSizing >= 0 && this->dataFractionUsedForSizing > 0) {
      85              :         // back and forth if dataConstantUsedForSizing should be > or >= 0 to make this work for AutoCalculate
      86          268 :         this->autoSizedValue = this->dataConstantUsedForSizing * this->dataFractionUsedForSizing;
      87              :     } else {
      88         3496 :         if (this->curZoneEqNum > 0) {
      89         1977 :             if (!this->wasAutoSized && !this->sizingDesRunThisZone) {
      90           86 :                 this->autoSizedValue = _originalValue;
      91         1891 :             } else if (this->zoneEqSizing(this->curZoneEqNum).DesignSizeFromParent) {
      92            1 :                 this->autoSizedValue = this->zoneEqSizing(this->curZoneEqNum).DesHeatingLoad;
      93              :             } else {
      94         1890 :                 if (this->dataCoilIsSuppHeater && this->suppHeatCap > 0.0) {
      95          356 :                     NominalCapacityDes = this->suppHeatCap;
      96          356 :                     if (this->dataFlowUsedForSizing > 0.0) {
      97            0 :                         DesVolFlow = this->dataFlowUsedForSizing;
      98              :                     }
      99         1534 :                 } else if (this->zoneEqSizing(this->curZoneEqNum).HeatingCapacity) {
     100          143 :                     NominalCapacityDes = this->zoneEqSizing(this->curZoneEqNum).DesHeatingLoad;
     101          143 :                     if (this->dataFlowUsedForSizing > 0.0) {
     102            4 :                         DesVolFlow = this->dataFlowUsedForSizing;
     103              :                     }
     104         1391 :                 } else if (this->dataCoolCoilCap > 0.0 && this->dataFlowUsedForSizing > 0.0) {
     105           85 :                     NominalCapacityDes = this->dataCoolCoilCap;
     106           85 :                     DesVolFlow = this->dataFlowUsedForSizing;
     107         2612 :                 } else if (int(this->finalZoneSizing.size()) > 0 &&
     108         1306 :                            this->finalZoneSizing(this->curZoneEqNum).DesHeatMassFlow >= HVAC::SmallMassFlow) {
     109         1296 :                     if (this->dataFlowUsedForSizing > 0.0) {
     110           18 :                         DesVolFlow = this->dataFlowUsedForSizing;
     111              :                     }
     112         1296 :                     if (this->termUnitPIU && (this->curTermUnitSizingNum > 0)) {
     113            1 :                         Real64 const MinPriFlowFrac = this->termUnitSizing(this->curTermUnitSizingNum).MinPriFlowFrac;
     114            1 :                         if (this->termUnitSizing(this->curTermUnitSizingNum).InducesPlenumAir) {
     115            1 :                             CoilInTemp = (this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatCoilInTempTU * MinPriFlowFrac) +
     116            1 :                                          (this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).ZoneRetTempAtHeatPeak * (1.0 - MinPriFlowFrac));
     117              :                         } else {
     118            0 :                             CoilInTemp = (this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatCoilInTempTU * MinPriFlowFrac) +
     119            0 :                                          (this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).ZoneTempAtHeatPeak * (1.0 - MinPriFlowFrac));
     120              :                         }
     121         1296 :                     } else if (this->termUnitIU && (this->curTermUnitSizingNum > 0)) {
     122            0 :                         CoilInTemp = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).ZoneTempAtHeatPeak;
     123            0 :                         CoilInHumRat = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).ZoneHumRatAtHeatPeak;
     124         1295 :                     } else if (this->termUnitSingDuct && (this->curTermUnitSizingNum > 0)) {
     125          317 :                         CoilInTemp = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatCoilInTempTU;
     126          317 :                         CoilInHumRat = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatCoilInHumRatTU;
     127              :                     } else {
     128              :                         // all other components calculate coil inlet condition based on actual, not design, OA fraction (e.g., FanCoil)
     129          978 :                         if (DesVolFlow > 0.0) {
     130           18 :                             DesMassFlow = DesVolFlow * state.dataEnvrn->StdRhoAir;
     131              :                         } else {
     132          960 :                             DesMassFlow = this->finalZoneSizing(this->curZoneEqNum).DesHeatMassFlow;
     133              :                         }
     134          978 :                         CoilInTemp = this->setHeatCoilInletTempForZoneEqSizing(
     135          978 :                             this->setOAFracForZoneEqSizing(state, DesMassFlow, zoneEqSizing(this->curZoneEqNum)),
     136          978 :                             zoneEqSizing(this->curZoneEqNum),
     137          978 :                             finalZoneSizing(this->curZoneEqNum));
     138          978 :                         CoilInHumRat = this->setHeatCoilInletHumRatForZoneEqSizing(
     139          978 :                             this->setOAFracForZoneEqSizing(state, DesMassFlow, zoneEqSizing(this->curZoneEqNum)),
     140          978 :                             zoneEqSizing(this->curZoneEqNum),
     141          978 :                             finalZoneSizing(this->curZoneEqNum));
     142              :                     }
     143         1296 :                     if ((this->termUnitSingDuct || this->termUnitPIU) && (this->curTermUnitSizingNum > 0)) {
     144          318 :                         CoilOutTemp = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).HeatDesTemp;
     145          318 :                         CoilOutHumRat = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).HeatDesHumRat;
     146          318 :                         Real64 const CpAir = Psychrometrics::PsyCpAirFnW(CoilOutHumRat);
     147          318 :                         DesCoilLoad = CpAir * state.dataEnvrn->StdRhoAir * this->termUnitSizing(this->curTermUnitSizingNum).AirVolFlow *
     148          318 :                                       (CoilOutTemp - CoilInTemp);
     149          318 :                         DesVolFlow = this->termUnitSizing(this->curTermUnitSizingNum).AirVolFlow;
     150         1296 :                     } else if (this->termUnitIU && (this->curTermUnitSizingNum > 0)) {
     151            0 :                         if (this->termUnitSizing(this->curTermUnitSizingNum).InducRat > 0.01) {
     152            0 :                             DesVolFlow = this->termUnitSizing(this->curTermUnitSizingNum).AirVolFlow /
     153            0 :                                          this->termUnitSizing(this->curTermUnitSizingNum).InducRat;
     154            0 :                             Real64 const CpAir = Psychrometrics::PsyCpAirFnW(this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).HeatDesHumRat);
     155              :                             // the design heating coil load is the zone load minus whatever the central system does.Note that
     156              :                             // DesHeatCoilInTempTU is really the primary air inlet temperature for the unit.
     157            0 :                             DesCoilLoad = this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatLoad -
     158            0 :                                           (CpAir * state.dataEnvrn->StdRhoAir * DesVolFlow *
     159            0 :                                            (this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).DesHeatCoilInTempTU -
     160            0 :                                             this->termUnitFinalZoneSizing(this->curTermUnitSizingNum).ZoneTempAtHeatPeak));
     161              :                         } else {
     162            0 :                             DesCoilLoad = 0.0;
     163              :                         }
     164            0 :                     } else {
     165          978 :                         CoilOutTemp = this->finalZoneSizing(this->curZoneEqNum).HeatDesTemp;
     166          978 :                         CoilOutHumRat = this->finalZoneSizing(this->curZoneEqNum).HeatDesHumRat;
     167          978 :                         Real64 const CpAir = Psychrometrics::PsyCpAirFnW(CoilOutHumRat);
     168          978 :                         DesCoilLoad = CpAir * this->finalZoneSizing(this->curZoneEqNum).DesHeatMassFlow * (CoilOutTemp - CoilInTemp);
     169          978 :                         DesVolFlow = this->finalZoneSizing(this->curZoneEqNum).DesHeatMassFlow / state.dataEnvrn->StdRhoAir;
     170              :                     }
     171         1296 :                     NominalCapacityDes = max(0.0, DesCoilLoad);
     172              :                 } else {
     173           10 :                     NominalCapacityDes = 0.0;
     174           10 :                     CoilOutTemp = -999.0;
     175              :                 }
     176         1890 :                 if (this->dataCoolCoilCap > 0.0) {
     177           86 :                     this->autoSizedValue = NominalCapacityDes * this->dataHeatSizeRatio;
     178              :                 } else {
     179         1804 :                     this->autoSizedValue = NominalCapacityDes * this->dataHeatSizeRatio * this->dataFracOfAutosizedHeatingCapacity;
     180              :                 }
     181         1890 :                 if (state.dataGlobal->DisplayExtraWarnings && this->autoSizedValue <= 0.0) {
     182            0 :                     ShowWarningMessage(state,
     183            0 :                                        this->callingRoutine + ": Potential issue with equipment sizing for " + this->compType + ' ' + this->compName);
     184            0 :                     ShowContinueError(state, format("...Rated Total Heating Capacity = {:.2T} [W]", this->autoSizedValue));
     185            0 :                     if (this->zoneEqSizing(this->curZoneEqNum).HeatingCapacity ||
     186            0 :                         (this->dataCoolCoilCap > 0.0 && this->dataFlowUsedForSizing > 0.0)) {
     187            0 :                         ShowContinueError(state,
     188            0 :                                           format("...Capacity passed by parent object to size child component = {:.2T} [W]", NominalCapacityDes));
     189              :                     } else {
     190            0 :                         if (CoilOutTemp > -999.0) {
     191            0 :                             ShowContinueError(state, format("...Air flow rate used for sizing = {:.5T} [m3/s]", DesVolFlow));
     192            0 :                             ShowContinueError(state, format("...Coil inlet air temperature used for sizing = {:.2T} [C]", CoilInTemp));
     193            0 :                             ShowContinueError(state, format("...Coil outlet air temperature used for sizing = {:.2T} [C]", CoilOutTemp));
     194              :                         } else {
     195            0 :                             ShowContinueError(state, "...Capacity used to size child component set to 0 [W]");
     196              :                         }
     197              :                     }
     198              :                 }
     199              :             }
     200         1519 :         } else if (this->curSysNum > 0) {
     201         1519 :             if (!this->wasAutoSized && !this->sizingDesRunThisAirSys) {
     202          255 :                 this->autoSizedValue = _originalValue;
     203              :             } else {
     204         1264 :                 if (this->curOASysNum > 0) {
     205           30 :                     if (this->oaSysEqSizing(this->curOASysNum).AirFlow) {
     206            0 :                         DesVolFlow = this->oaSysEqSizing(this->curOASysNum).AirVolFlow;
     207           30 :                     } else if (this->oaSysEqSizing(this->curOASysNum).HeatingAirFlow) {
     208            1 :                         DesVolFlow = this->oaSysEqSizing(this->curOASysNum).HeatingAirVolFlow;
     209           29 :                     } else if (this->outsideAirSys(this->curOASysNum).AirLoopDOASNum > -1) {
     210            1 :                         DesVolFlow =
     211            1 :                             this->airloopDOAS[this->outsideAirSys(this->curOASysNum).AirLoopDOASNum].SizingMassFlow / state.dataEnvrn->StdRhoAir;
     212              :                     } else {
     213           28 :                         DesVolFlow = this->finalSysSizing(this->curSysNum).DesOutAirVolFlow;
     214              :                     }
     215              :                 } else {
     216         1234 :                     if (this->finalSysSizing(this->curSysNum).HeatingCapMethod == DataSizing::FractionOfAutosizedHeatingCapacity) {
     217            1 :                         this->dataFracOfAutosizedHeatingCapacity = this->finalSysSizing(this->curSysNum).FractionOfAutosizedHeatingCapacity;
     218              :                     }
     219         1234 :                     if (this->dataFlowUsedForSizing > 0.0) {
     220          494 :                         DesVolFlow = this->dataFlowUsedForSizing;
     221          740 :                     } else if (this->unitarySysEqSizing(this->curSysNum).AirFlow) {
     222          116 :                         DesVolFlow = this->unitarySysEqSizing(this->curSysNum).AirVolFlow;
     223          624 :                     } else if (this->unitarySysEqSizing(this->curSysNum).HeatingAirFlow) {
     224          134 :                         DesVolFlow = this->unitarySysEqSizing(this->curSysNum).HeatingAirVolFlow;
     225              :                     } else {
     226          490 :                         if (this->curDuctType == HVAC::AirDuctType::Main) {
     227          490 :                             if (this->finalSysSizing(this->curSysNum).SysAirMinFlowRat > 0.0 && !this->dataDesicRegCoil) {
     228          486 :                                 DesVolFlow =
     229          486 :                                     this->finalSysSizing(this->curSysNum).SysAirMinFlowRat * this->finalSysSizing(this->curSysNum).DesMainVolFlow;
     230              :                             } else {
     231            4 :                                 DesVolFlow = this->finalSysSizing(this->curSysNum).DesMainVolFlow;
     232              :                             }
     233            0 :                         } else if (this->curDuctType == HVAC::AirDuctType::Cooling) {
     234            0 :                             if (this->finalSysSizing(this->curSysNum).SysAirMinFlowRat > 0.0 && !this->dataDesicRegCoil) {
     235            0 :                                 DesVolFlow =
     236            0 :                                     this->finalSysSizing(this->curSysNum).SysAirMinFlowRat * this->finalSysSizing(this->curSysNum).DesCoolVolFlow;
     237              :                             } else {
     238            0 :                                 DesVolFlow = this->finalSysSizing(this->curSysNum).DesCoolVolFlow;
     239              :                             }
     240            0 :                         } else if (this->curDuctType == HVAC::AirDuctType::Heating) {
     241            0 :                             DesVolFlow = this->finalSysSizing(this->curSysNum).DesHeatVolFlow;
     242              :                         } else {
     243            0 :                             DesVolFlow = this->finalSysSizing(this->curSysNum).DesMainVolFlow;
     244              :                         }
     245              :                     }
     246              :                 }
     247         1264 :                 DesMassFlow = state.dataEnvrn->StdRhoAir * DesVolFlow;
     248              :                 // get the outside air fraction
     249         1264 :                 if (this->curOASysNum > 0) {
     250           30 :                     OutAirFrac = 1.0;
     251         1234 :                 } else if (this->finalSysSizing(this->curSysNum).HeatOAOption == DataSizing::OAControl::MinOA) {
     252         1191 :                     if (DesVolFlow > 0.0) {
     253         1191 :                         OutAirFrac = this->finalSysSizing(this->curSysNum).DesOutAirVolFlow / DesVolFlow;
     254              :                     } else {
     255            0 :                         OutAirFrac = 1.0;
     256              :                     }
     257         1191 :                     OutAirFrac = std::min(1.0, std::max(0.0, OutAirFrac));
     258              :                 } else {
     259           43 :                     OutAirFrac = 1.0;
     260              :                 }
     261              :                 // coil inlet temperature
     262         1264 :                 if (this->curOASysNum == 0 && this->primaryAirSystem(this->curSysNum).NumOAHeatCoils > 0) {
     263           27 :                     CoilInTemp = OutAirFrac * this->finalSysSizing(this->curSysNum).PreheatTemp +
     264           27 :                                  (1.0 - OutAirFrac) * this->finalSysSizing(this->curSysNum).HeatRetTemp;
     265           27 :                     CoilInHumRat = OutAirFrac * this->finalSysSizing(this->curSysNum).PreheatHumRat +
     266           27 :                                    (1.0 - OutAirFrac) * this->finalSysSizing(this->curSysNum).HeatRetHumRat; // include humrat for coil sizing reports
     267         1237 :                 } else if (this->curOASysNum > 0 && this->outsideAirSys(this->curOASysNum).AirLoopDOASNum > -1) {
     268            1 :                     CoilInTemp = this->airloopDOAS[this->outsideAirSys(this->curOASysNum).AirLoopDOASNum].HeatOutTemp;
     269              :                 } else {
     270         1236 :                     CoilInTemp = OutAirFrac * this->finalSysSizing(this->curSysNum).HeatOutTemp +
     271         1236 :                                  (1.0 - OutAirFrac) * this->finalSysSizing(this->curSysNum).HeatRetTemp;
     272         1236 :                     CoilInHumRat = OutAirFrac * this->finalSysSizing(this->curSysNum).HeatOutHumRat +
     273         1236 :                                    (1.0 - OutAirFrac) * this->finalSysSizing(this->curSysNum).HeatRetHumRat; // include humrat for coil sizing reports
     274              :                 }
     275              :                 // coil load
     276         1264 :                 if (this->curOASysNum > 0) {
     277           30 :                     if (this->oaSysEqSizing(this->curOASysNum).HeatingCapacity) {
     278            0 :                         DesCoilLoad = this->oaSysEqSizing(this->curOASysNum).DesHeatingLoad;
     279           30 :                     } else if (this->dataDesicRegCoil) {
     280            0 :                         DesCoilLoad = CpAirStd * DesMassFlow * (this->dataDesOutletAirTemp - this->dataDesInletAirTemp);
     281            0 :                         CoilOutTemp = this->dataDesOutletAirTemp;
     282           30 :                     } else if (this->outsideAirSys(this->curOASysNum).AirLoopDOASNum > -1) {
     283            2 :                         DesCoilLoad = CpAirStd * DesMassFlow *
     284            1 :                                       (this->airloopDOAS[this->outsideAirSys(this->curOASysNum).AirLoopDOASNum].PreheatTemp - CoilInTemp);
     285            1 :                         CoilOutTemp = this->airloopDOAS[outsideAirSys(this->curOASysNum).AirLoopDOASNum].PreheatTemp;
     286              :                     } else {
     287           29 :                         DesCoilLoad = CpAirStd * DesMassFlow * (this->finalSysSizing(this->curSysNum).PreheatTemp - CoilInTemp);
     288           29 :                         CoilOutTemp = this->finalSysSizing(this->curSysNum).PreheatTemp;
     289           29 :                         CoilOutHumRat = this->finalSysSizing(this->curSysNum).PreheatHumRat;
     290              :                     }
     291              :                 } else {
     292         1234 :                     if (this->unitarySysEqSizing(this->curSysNum).HeatingCapacity) {
     293          282 :                         DesCoilLoad = this->unitarySysEqSizing(this->curSysNum).DesHeatingLoad;
     294          282 :                         CoilOutTemp = this->finalSysSizing(this->curSysNum).HeatSupTemp;
     295          282 :                         CoilOutHumRat = this->finalSysSizing(this->curSysNum).HeatSupHumRat;
     296          952 :                     } else if (this->dataDesicRegCoil) {
     297            0 :                         DesCoilLoad = CpAirStd * DesMassFlow * (this->dataDesOutletAirTemp - this->dataDesInletAirTemp);
     298            0 :                         CoilOutTemp = this->dataDesOutletAirTemp;
     299              :                     } else {
     300          952 :                         DesCoilLoad = CpAirStd * DesMassFlow * (this->finalSysSizing(this->curSysNum).HeatSupTemp - CoilInTemp);
     301          952 :                         CoilOutTemp = this->finalSysSizing(this->curSysNum).HeatSupTemp;
     302          952 :                         CoilOutHumRat = this->finalSysSizing(this->curSysNum).HeatSupHumRat;
     303              :                     }
     304              :                 }
     305         1264 :                 if (this->curSysNum <= state.dataHVACGlobal->NumPrimaryAirSys && this->airLoopControlInfo(this->curSysNum).UnitarySys) {
     306          663 :                     if (this->dataCoilIsSuppHeater) {
     307          179 :                         NominalCapacityDes = this->suppHeatCap;
     308          484 :                     } else if (this->dataCoolCoilCap > 0.0) {
     309           28 :                         NominalCapacityDes = this->dataCoolCoilCap;
     310              :                     } else {
     311              :                         // TRUE for all air loop parent equipment except UnitarySystem where flag is reset to FALSE after simulating
     312              :                         // This method allows downstream heating coils to size individually.Probably should do this for all air loop equipment
     313              :                         // ChangoverBypass model always sets AirLoopControlInfo%UnitarySys to FALSE so heating coil can individually size
     314          729 :                         if (this->airLoopControlInfo(this->curSysNum).UnitarySysSimulating &&
     315          729 :                             !Util::SameString(this->compType, "COIL:HEATING:WATER")) {
     316          267 :                             NominalCapacityDes = this->unitaryHeatCap;
     317              :                         } else {
     318          189 :                             if (DesCoilLoad >= HVAC::SmallLoad) {
     319          189 :                                 NominalCapacityDes = DesCoilLoad;
     320              :                             } else {
     321            0 :                                 NominalCapacityDes = 0.0;
     322              :                             }
     323              :                         }
     324              :                     }
     325          663 :                     DesCoilLoad = NominalCapacityDes;
     326         1201 :                 } else if (this->curSysNum <= state.dataHVACGlobal->NumPrimaryAirSys &&
     327          600 :                            this->finalSysSizing(this->curSysNum).HeatingCapMethod == DataSizing::CapacityPerFloorArea) {
     328            0 :                     NominalCapacityDes = this->finalSysSizing(this->curSysNum).HeatingTotalCapacity;
     329          601 :                 } else if (this->curSysNum <= state.dataHVACGlobal->NumPrimaryAirSys &&
     330         1200 :                            this->finalSysSizing(this->curSysNum).HeatingCapMethod == DataSizing::HeatingDesignCapacity &&
     331          599 :                            this->finalSysSizing(this->curSysNum).HeatingTotalCapacity > 0.0) {
     332            0 :                     NominalCapacityDes = this->finalSysSizing(this->curSysNum).HeatingTotalCapacity;
     333              :                 } else {
     334          601 :                     if (this->dataCoolCoilCap > 0.0) { // this line can't get executed with same logic above else
     335            4 :                         NominalCapacityDes = this->dataCoolCoilCap;
     336          597 :                     } else if (DesCoilLoad >= HVAC::SmallLoad) {
     337          564 :                         NominalCapacityDes = DesCoilLoad;
     338              :                     } else {
     339           33 :                         NominalCapacityDes = 0.0;
     340              :                     }
     341              :                 }
     342         1264 :                 this->autoSizedValue = NominalCapacityDes * this->dataHeatSizeRatio * this->dataFracOfAutosizedHeatingCapacity;
     343         1264 :                 if (state.dataGlobal->DisplayExtraWarnings && this->autoSizedValue <= 0.0) {
     344            0 :                     ShowWarningMessage(state,
     345            0 :                                        this->callingRoutine + ": Potential issue with equipment sizing for " + this->compType + ' ' + this->compName);
     346            0 :                     ShowContinueError(state, format("...Rated Total Heating Capacity = {:.2T} [W]", this->autoSizedValue));
     347            0 :                     if (CoilOutTemp > -999.0) {
     348            0 :                         ShowContinueError(state, format("...Air flow rate used for sizing = {:.5T} [m3/s]", DesVolFlow));
     349            0 :                         ShowContinueError(state, format("...Outdoor air fraction used for sizing = {:.2T}", OutAirFrac));
     350            0 :                         ShowContinueError(state, format("...Coil inlet air temperature used for sizing = {:.2T} [C]", CoilInTemp));
     351            0 :                         ShowContinueError(state, format("...Coil outlet air temperature used for sizing = {:.2T} [C]", CoilOutTemp));
     352              :                     } else {
     353            0 :                         ShowContinueError(state, format("...Capacity passed by parent object to size child component = {:.2T} [W]", DesCoilLoad));
     354              :                     }
     355              :                 }
     356              :             }
     357            0 :         } else if (this->dataNonZoneNonAirloopValue > 0) {
     358            0 :             this->autoSizedValue = this->dataNonZoneNonAirloopValue;
     359            0 :         } else if (!this->wasAutoSized) {
     360            0 :             this->autoSizedValue = this->originalValue;
     361              :         } else {
     362            0 :             std::string msg = this->callingRoutine + ' ' + this->compType + ' ' + this->compName + ", Developer Error: Component sizing incomplete.";
     363            0 :             ShowSevereError(state, msg);
     364            0 :             this->addErrorMessage(msg);
     365            0 :             msg = format("SizingString = {}, SizingResult = {:.1T}", this->sizingString, this->autoSizedValue);
     366            0 :             ShowContinueError(state, msg);
     367            0 :             this->addErrorMessage(msg);
     368            0 :             errorsFound = true;
     369            0 :         }
     370              :     }
     371         3764 :     if (!this->hardSizeNoDesignRun || this->dataScalableSizingON || this->dataScalableCapSizingON) {
     372         3523 :         if (this->wasAutoSized && this->dataFractionUsedForSizing == 0.0) {
     373              :             // Note: the VolFlowPerRatedTotCap check is not applicable for VRF-FluidTCtrl coil model, which implements variable flow fans and
     374              :             // determines capacity using physical calculations instead of emperical curves
     375         2820 :             bool FlagCheckVolFlowPerRatedTotCap = true;
     376         5640 :             if (Util::SameString(this->compType, "Coil:Cooling:DX:VariableRefrigerantFlow:FluidTemperatureControl") ||
     377         5640 :                 Util::SameString(this->compType, "Coil:Heating:DX:VariableRefrigerantFlow:FluidTemperatureControl")) {
     378           15 :                 FlagCheckVolFlowPerRatedTotCap = false;
     379              :             }
     380              : 
     381         2820 :             if (this->dataIsDXCoil && FlagCheckVolFlowPerRatedTotCap && this->autoSizedValue > 0.0) {
     382          137 :                 Real64 RatedVolFlowPerRatedTotCap = DesVolFlow / this->autoSizedValue;
     383          137 :                 if (RatedVolFlowPerRatedTotCap < HVAC::MinRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT]) {
     384           33 :                     if ((this->dataEMSOverride == 0.0) && state.dataGlobal->DisplayExtraWarnings && this->printWarningFlag) {
     385            1 :                         ShowWarningError(state, this->callingRoutine + ' ' + this->compType + ' ' + this->compName);
     386            2 :                         ShowContinueError(
     387            2 :                             state, "..." + this->sizingString + " will be limited by the minimum rated volume flow per rated total capacity ratio.");
     388            1 :                         ShowContinueError(state, format("...DX coil volume flow rate (m3/s ) = {:.6T}", DesVolFlow));
     389            1 :                         ShowContinueError(state, format("...Requested capacity (W ) = {:.3T}", this->autoSizedValue));
     390            1 :                         ShowContinueError(state, format("...Requested flow/capacity ratio (m3/s/W ) = {:.3T}", RatedVolFlowPerRatedTotCap));
     391            2 :                         ShowContinueError(state,
     392            2 :                                           format("...Minimum flow/capacity ratio (m3/s/W ) = {:.3T}",
     393            1 :                                                  HVAC::MinRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT]));
     394              :                     }
     395              : 
     396           33 :                     DXFlowPerCapMinRatio = (DesVolFlow / HVAC::MinRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT]) /
     397           33 :                                            this->autoSizedValue; // set DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio
     398           33 :                     this->autoSizedValue = DesVolFlow / HVAC::MinRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT];
     399              : 
     400           33 :                     if ((this->dataEMSOverride == 0.0) && state.dataGlobal->DisplayExtraWarnings && this->printWarningFlag) {
     401            1 :                         ShowContinueError(state, format("...Adjusted capacity ( W ) = {:.3T}", this->autoSizedValue));
     402              :                     }
     403          104 :                 } else if (RatedVolFlowPerRatedTotCap > HVAC::MaxRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT]) {
     404            5 :                     if ((this->dataEMSOverride == 0.0) && state.dataGlobal->DisplayExtraWarnings && this->printWarningFlag) {
     405            0 :                         ShowWarningError(state, this->callingRoutine + ' ' + this->compType + ' ' + this->compName);
     406            0 :                         ShowContinueError(
     407            0 :                             state, "..." + this->sizingString + " will be limited by the maximum rated volume flow per rated total capacity ratio.");
     408            0 :                         ShowContinueError(state, format("...DX coil volume flow rate ( m3/s ) = {:.6T}", DesVolFlow));
     409            0 :                         ShowContinueError(state, format("...Requested capacity ( W ) = {:.3T}", this->autoSizedValue));
     410            0 :                         ShowContinueError(state, format("...Requested flow/capacity ratio ( m3/s/W ) = {:.3T}", RatedVolFlowPerRatedTotCap));
     411            0 :                         ShowContinueError(state,
     412            0 :                                           format("...Maximum flow/capacity ratio ( m3/s/W ) = {:.3T}",
     413            0 :                                                  HVAC::MaxRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT]));
     414              :                     }
     415              : 
     416            5 :                     DXFlowPerCapMaxRatio = DesVolFlow / HVAC::MaxRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT] /
     417            5 :                                            this->autoSizedValue; // set DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio
     418            5 :                     this->autoSizedValue = DesVolFlow / HVAC::MaxRatedVolFlowPerRatedTotCap[(int)state.dataHVACGlobal->DXCT];
     419              : 
     420            5 :                     if ((this->dataEMSOverride == 0.0) && state.dataGlobal->DisplayExtraWarnings && this->printWarningFlag) {
     421            0 :                         ShowContinueError(state, format("...Adjusted capacity ( W ) = {:.3T}", this->autoSizedValue));
     422              :                     }
     423              :                 }
     424              :             }
     425              :         }
     426              :     }
     427              : 
     428              :     // override sizing string
     429         3764 :     if (this->overrideSizeString) {
     430            9 :         if (this->isEpJSON) {
     431            0 :             this->sizingString = "nominal_capacity [W]";
     432              :         }
     433              :     }
     434         3764 :     if (this->dataScalableCapSizingON) {
     435           10 :         switch (this->zoneEqSizing(this->curZoneEqNum).SizingMethod(HVAC::HeatingCapacitySizing)) {
     436            5 :         case DataSizing::CapacityPerFloorArea: {
     437            5 :             this->sizingStringScalable = "(scaled by capacity / area) ";
     438            5 :         } break;
     439            4 :         case DataSizing::FractionOfAutosizedHeatingCapacity:
     440              :         case DataSizing::FractionOfAutosizedCoolingCapacity: {
     441            4 :             this->sizingStringScalable = "(scaled by fractional multiplier) ";
     442            4 :         } break;
     443            1 :         default:
     444            1 :             break;
     445              :         }
     446              :     }
     447              : 
     448         3764 :     this->selectSizerOutput(state, errorsFound);
     449              : 
     450         3764 :     if (this->isCoilReportObject) {
     451         2180 :         if (CoilInTemp > -999.0) { // set inlet air properties used during capacity sizing if available, allow for negative winter temps
     452         1546 :             state.dataRptCoilSelection->coilSelectionReportObj->setCoilEntAirTemp(
     453         1546 :                 state, this->compName, this->compType, CoilInTemp, this->curSysNum, this->curZoneEqNum);
     454         1546 :             state.dataRptCoilSelection->coilSelectionReportObj->setCoilEntAirHumRat(state, this->compName, this->compType, CoilInHumRat);
     455              :         }
     456         2180 :         if (CoilOutTemp > -999.0) { // set outlet air properties used during capacity sizing if available
     457         1546 :             state.dataRptCoilSelection->coilSelectionReportObj->setCoilLvgAirTemp(state, this->compName, this->compType, CoilOutTemp);
     458         1546 :             state.dataRptCoilSelection->coilSelectionReportObj->setCoilLvgAirHumRat(state, this->compName, this->compType, CoilOutHumRat);
     459              :         }
     460         2180 :         state.dataRptCoilSelection->coilSelectionReportObj->setCoilAirFlow(state, this->compName, this->compType, DesVolFlow, this->wasAutoSized);
     461         2180 :         Real64 constexpr FanCoolLoad = 0.0;
     462         2180 :         Real64 constexpr TotCapTempModFac = 1.0;
     463         2180 :         state.dataRptCoilSelection->coilSelectionReportObj->setCoilHeatingCapacity(state,
     464         2180 :                                                                                    this->compName,
     465         2180 :                                                                                    this->compType,
     466              :                                                                                    this->autoSizedValue,
     467         2180 :                                                                                    this->wasAutoSized,
     468              :                                                                                    this->curSysNum,
     469              :                                                                                    this->curZoneEqNum,
     470              :                                                                                    this->curOASysNum,
     471              :                                                                                    FanCoolLoad,
     472              :                                                                                    TotCapTempModFac,
     473              :                                                                                    DXFlowPerCapMinRatio,
     474              :                                                                                    DXFlowPerCapMaxRatio);
     475              :     }
     476         3764 :     return this->autoSizedValue;
     477              : }
     478              : 
     479            0 : void HeatingCapacitySizer::clearState()